Error description

  • Adding vCenter via Storage Insights GUI is successful even when
    user only has Read-Only access and no 'Browse Datastore'
    privilege. Test Connection and Discovery completes with no
    error, but initial / daily Probe fails with no permission to
    retrieve datastore data and exit with RC -95.
    
    Since no probe data is ever collected successfully, all ESXi
    hosts were added as Not Monitored and Other OS Type instead of
    expected ESXi OS Type with associated vCenter.
    
    In ideal situations, the add vCenter should fail if the
    required user privileges (Read Only + Browse Datastore) are not
    present.
    
    ____________________________________
    Problem as described by customer:
    vCenter not visible in Storage Insights and not able to modify
    credentials.
    
    Initial customer impact (low/med/high): low
    

Local fix

  • Update privileges for the user from Read-Only on the vCenter
    to 'Read-Only' + 'Browse Datastore' and wait for the next probe
    to finish.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users monitoring vCenter                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Adding vCenter via Storage Insights GUI is successful even   *
    * when user only has Read-Only access and does not have        *
    * 'Browse Datastore' privilege. Test Connection and Discovery  *
    * completes with no error, but initial / daily probe fails     *
    * with no                                                      *
    * permission to retrieve datastore data and exit with RC -95.  *
    *                                                              *
    * Since no probe data is ever collected successfully, all ESXi *
    * hosts get added as 'Not Monitored', with 'Other OS' type     *
    * instead of the expected ESXi OS type with associated         *
    * vCenter.                                                     *
    *                                                              *
    * In ideal situations, the add vCenter should fail if the      *
    * required user privileges (Read Only + Browse Datastore)      *
    * are not present.                                             *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 2Q25   [ 54X-IBM-SI ]
    ( release target 2Q 2025 / April )
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT47381

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    54X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-12-06

  • Closed date

    2025-04-17

  • Last modified date

    2025-04-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels