This technical note provides guidance for installing IBM Guardium Data Protection patch 11.0p9990.
Content
Patch information
- Patch file name: SqlGuard-11.0p9990_Mar_24_2025.tgz.enc.sig
- MD5 checksum: 7eae9f3aa65c0805a97b404cb731571c
Finding the patch
- Select the following options to download this patch on the IBM Fix Central website and click Continue.
- Product selector: IBM Security Guardium
- Installed Version: 11.0
- Platform: All
- On the "Identify fixes" page, select Browse for fixes and click Continue.
- On the "Select fixes" page, select Appliance patch (GPU and Ad-Hoc). Then, enter the patch information in the Filter fix details field to locate the patch.
For information about Guardium patch types and naming conventions, see the Understanding Guardium patch types and patch names support document.
Attention
Renewed Guardium patch signing certificate
Guardium appliance patches are signed by an internal certificate to validate that the patch is created by Guardium. Unsigned patch files cannot be installed. This patch, 11.0p9990, is signed by a new patch signing certificate. Therefore, to install this patch, the patch signing certificate on your Guardium appliance must first be updated by installing ad hoc patch 11.0p1057 (see release note) or an appropriate appliance bundle listed in IBM Guardium - Patch signing certificate set to expire in March 2025.
Prerequisites
Guardium Data Protection 11.0
Overview
The purpose of the patch is to resolve known rpm conflict issues that can prevent GPU or upgrade patch installation. Health check patch 11.0p9997 shows whether 11.0p9990 installation is required to proceed with upgrade.
Basic steps:
- Install the latest Guardium Data Protection health check patch 11.0p9997.
- If the health check patch fails, check the GUI "Health check log" report.
- Right-click the latest health check patch installation and drill down to the Details report.
- Review the details to see if any require installation of patch 11.0p9990.
- If patch 11.0p9990 is required, install it and then re-install health check patch 11.0p9997.
Fixes
|
Issue key
|
Summary
|
|
GRD-76591
|
GPU 11.0p500 installation fails if patch 11.0p485 is applied.
If you see the following error message after you run the health check patch, then install patch 11.0p9990: ERROR for p500 install: p500 install will fail if specific device-mapper-multipath rpm is present. Other bundles will succeed. Check p9997 release notes for steps to resolve. |
|
GRD-88232
|
GPU 11.0p500 installation fails if patch 11.0.p492 is applied.
If you see the following error message after you run the health check patch, then install patch 11.0p9990: ERROR for p500: Incompatible bind rpm found. Install 11.0p9990 to resolve.
|
|
GRD-95577
|
Ad hoc patch 11.0p1057 installation fails if patch 11.0p494 is applied and health check patch 11.0p9997 cannot be installed again.
If you see the following error message after you run the health check patch, then install patch 11.0p9990: Patch not compatible with this appliance. This patch contains an old access format.
|
[{"Type":"MASTER","Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"ARM Category":[{"code":"a8m0z000000Gp0JAAS","label":"APPLIANCE"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.0.0;11.1.0;11.2.0;11.3.0;11.4.0;11.5.0"}]