Error description

  • SCRT may fail to produce a report for z/OS 1.7 guests running
    under z/VM. The JOBLOG will show:
    ******* SCRT VERSION 29.1.0 ******
    
    SCRTTOOL603: SCRT PROCESSING HAS FAILED DUE TO A SEVERE ERROR.
    
    IBM Sub-Capacity Reporting Tool 29.1.0
    
    Build id: 20220922-1052
    
    Date and time of error: 2023-09-25T14:30:00.033
    
    java.lang.NullPointerException
    
     at com.ibm.scrt.data.aj.i(aj.java:131)
    
     at com.ibm.scrt.data.al.k(al.java:589)
    
     at com.ibm.scrt.main.MainSCRT.l(MainSCRT.java:523)
    
     at com.ibm.scrt.main.MainSCRT.d(MainSCRT.java:521)
    
     at
    com.ibm.scrt.main.MainSCRT.zOSBatchEntryPoint(MainSCRT.java:309)
    
     at com.ibm.scrt.SCRTe.main(SCRTe.java:48)
    

Local fix

  • Ensure SMF APAR OA20314 is applied
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: SCRT users running z/OS 1.7 guests under     *
    *                 z/VM without SMF APAR OA20314 applied.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: SCRT fails due to required information  *
    *                      not being present in the SMF89 records. *
    ****************************************************************
    * RECOMMENDATION: Apply SMF APAR OA20314 to all z/VM guests.   *
    ****************************************************************
    SCRT fails due to required information not being present in the
    SMF89 records.  SCRT does not create the minimum data structures
    necessary to create a report or issue a proper error message.
    

Problem conclusion

Temporary fix

Comments

  • SCRT 30.1.4 is enhanced to avoid the Null Pointer Exception.
    SMF APAR OA20314 is required to be applied to the guests in
    order to produce a correct SCRT report.
    

APAR Information

  • APAR number

    OA65591

  • Reported component name

    SCRT (JAVA)

  • Reported component ID

    5752SCRT2

  • Reported release

    7D0

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-09-25

  • Closed date

    2024-12-03

  • Last modified date

    2024-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7D0"}]

Document Information

Modified date:
05 December 2024