APAR status
Closed as fixed if next.
Error description
SCRT may fail to produce a report for z/OS 1.7 guests running under z/VM. The JOBLOG will show: ******* SCRT VERSION 29.1.0 ****** SCRTTOOL603: SCRT PROCESSING HAS FAILED DUE TO A SEVERE ERROR. IBM Sub-Capacity Reporting Tool 29.1.0 Build id: 20220922-1052 Date and time of error: 2023-09-25T14:30:00.033 java.lang.NullPointerException at com.ibm.scrt.data.aj.i(aj.java:131) at com.ibm.scrt.data.al.k(al.java:589) at com.ibm.scrt.main.MainSCRT.l(MainSCRT.java:523) at com.ibm.scrt.main.MainSCRT.d(MainSCRT.java:521) at com.ibm.scrt.main.MainSCRT.zOSBatchEntryPoint(MainSCRT.java:309) at com.ibm.scrt.SCRTe.main(SCRTe.java:48)
Local fix
Ensure SMF APAR OA20314 is applied
Problem summary
**************************************************************** * USERS AFFECTED: SCRT users running z/OS 1.7 guests under * * z/VM without SMF APAR OA20314 applied. * **************************************************************** * PROBLEM DESCRIPTION: SCRT fails due to required information * * not being present in the SMF89 records. * **************************************************************** * RECOMMENDATION: Apply SMF APAR OA20314 to all z/VM guests. * **************************************************************** SCRT fails due to required information not being present in the SMF89 records. SCRT does not create the minimum data structures necessary to create a report or issue a proper error message.
Problem conclusion
Temporary fix
Comments
SCRT 30.1.4 is enhanced to avoid the Null Pointer Exception. SMF APAR OA20314 is required to be applied to the guests in order to produce a correct SCRT report.
APAR Information
APAR number
OA65591
Reported component name
SCRT (JAVA)
Reported component ID
5752SCRT2
Reported release
7D0
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-25
Closed date
2024-12-03
Last modified date
2024-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7D0"}]
Document Information
Modified date:
05 December 2024