APAR status
Closed as program error.
Error description
The OIDC TAI emits a nonce value that is less than 22 characters. Although the OIDC specification does not provide a minimum number of characters for the nonce value, the US login.gov requirements for OIDC, https://developers.login.gov/oidc/authorization/ , specifies that a minimum of 22 characters is required for the nonce length.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM WebSphere Application Server users of * * OIDC * **************************************************************** * PROBLEM DESCRIPTION: The OIDC TAI emits a nonce value that * * is * * less than 22 characters. * **************************************************************** * RECOMMENDATION: Install a fix pack or interim fix that * * contains this APAR. * **************************************************************** The OIDC TAI emits a nonce value that is less than 22 characters. Some OpenID Connect providers might reject a request that has a nonce value that is less than 22 characters.
Problem conclusion
The OIDC TAI is updated to emit a nonce value that is 22 characters or more. The fix for this APAR is targeted for inclusion in fix pack 8.5.5.27 and 9.0.5.22. For more information, see 'Recommended Updates for WebSphere Application Server': https://www.ibm.com/support/pages/node/715553
Temporary fix
Comments
APAR Information
APAR number
PH62934
Reported component name
WEBSPHERE APP S
Reported component ID
5724J0800
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-08-26
Closed date
2024-11-25
Last modified date
2024-11-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE APP S
Fixed component ID
5724J0800
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Line of Business":{"code":"LOB67","label":"IT Automation \u0026 App Modernization"}}]