A fix is available
APAR status
Closed as program error.
Error description
A COBOL program with COMPUTE A=B+C, where A,B,C are defined as 18 digit binary, uses about 50% more CPU at execution time when compiled with previous versions of the compiler. ADDITIONAL SYMPTOMS: PERFM
Local fix
BYPASS/CIRCUMVENTION: Compile at OPT(1|2). RECOVERY ACTION: Apply PTF
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs with OPT(0), TRUNC(OPT|STD) and * * performs 18-digit binary additions and * * subtractions numerous times. * **************************************************************** * PROBLEM DESCRIPTION: Program may perform worse than when * * compiled with previous versions of the * * compiler. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler was performing 18-digit additions and subtractions of binary data items as PACKED-DECIMAL to avoid potential overflow issues when invalid data was used, hurting performance for clients using only valid data.
Problem conclusion
The compiler was fixed to perform 18-digit addition and subtraction in binary if NOINVDATA is specified.
Temporary fix
Comments
APAR Information
APAR number
PH64241
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-20
Closed date
2024-11-21
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI99158
UP24/12/03 P F412
R631 PSY UI99159
UP24/12/03 P F412
R632 PSY UI99160
UP24/12/03 P F412
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: