A fix is available
APAR status
Closed as program error.
Error description
This APAR contains CMS service for z/VM version 7 release 4 Fix Pack 2.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of z/VM * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** When building CMS Pipelines filter package with a large REXX program, an incorrect module may be generated. No error messages are issued when building the module, but when using the filter package, reference to an included filter may cause an error message DMSEXE175E Invalid EXEC command
Problem conclusion
The default for PIPGFTXT is to compress the REXX programs that are included in the filter package. This may result in long source lines. The code in PIPGFTXT has been fixed to correctly compute the length of long lines as well. This ensures a working filter package is created.
Temporary fix
Comments
APAR Information
APAR number
VM66809
Reported component name
VM CMS
Reported component ID
568411201
Reported release
740
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-14
Closed date
2024-11-20
Last modified date
2025-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM90489
Modules/Macros
DMSINL DMSLVLTB PIPGFTXT 7VMCMS40
Fix information
Fixed component name
VM CMS
Fixed component ID
568411201
Applicable component levels
R740 PSY UM90489
UP24/11/26 P 2501
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG27M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"740","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]
Document Information
Modified date: