Fix Readme
Abstract
When selecting System Monitors in IBM Navigator for i users are getting "Runtime Error Occurred: Check the error log for previous error condition.
Content
When selecting System Monitors in IBM Navigator for i users are getting "Runtime Error Occurred: Check the error log for previous error condition. Looking in the Monitor.log (located in /QIBM/UserData/OS400/Navigator/config/MONITOR/) there is the following error:
java.lang.NullPointerException
at java.io.Reader.<init>(Reader.java:90)
at java.io.InputStreamReader.<init>(InputStreamReader.java:86)
at com.ibm.as400.mc.common.DataBaseInitializer.getDbInitScript(DataBaseInitializer.java:419)
at com.ibm.as400.mc.common.DataBaseInitializer.executeScript(DataBaseInitializer.java:356)
at com.ibm.as400.mc.common.DataBaseInitializer.doInitialize(DataBaseInitializer.java:336)
at com.ibm.as400.mc.common.DataBaseInitializer.initialize(DataBaseInitializer.java:94)
at com.ibm.as400.mc.service.ManagementServer.initializeDatabase(ManagementServer.java:249)
at com.ibm.as400.mc.service.ManagementServer.main(ManagementServer.java:208)
The work around for this issue is
1) CHGJOB CCSID(37)
2) QSYS/SBMJOB CMD(CALL PGM(QSYSDIR/QINAVMNSRV) PARM(*START)) JOB(QINAVMNSRV) JOBD(QGPL/QDFTSVR) JOBQ(QSYS/QSYSNOMAX) OUTQ(*CURRENT) USER(QLWISVR) CURLIB(*CRTDFT) INLLIBL(*JOBD) INLASPGRP(*JOBD)
*********NOTE************
The fix is in the latest HTTP Group ptf (came out in July 2018)