APAR status
Closed as program error.
Error description
For unknown reasons (a possible reason is /tmp full), the update of RKM.conf was not able to obtain the KMIP port from a file. The code does not check for any error and continues to produce the kmipServerUri line with missing port number. Encrypted files may not be accessible due to this issue.
Local fix
On the problem node, remove the bad RKM.conf file then run a GPFS command to regenerate the RKM.conf file. For example, run mmlscluster.
Problem summary
For unknown reasons (a possible reason is /tmp full), the update of RKM.conf was not able to obtain the KMIP port from a file. The code does not check for any error and continues to produce the kmipServerUri line with missing port number. Encrypted files may not be accessible due to this issue.
Problem conclusion
This problem is fixed in 5.1.9.7 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale _apars.html Benefits of the solution: This fix ensures the KMIP port number is not null before producing the kmipServerUri line for RKM stanza. If error is detected, it stops processing and will not update the RKM.conf file. Errors will be logged in syslog and mmfs.log.In this fix, a /tmp file system full should not cause a null KMIP port number. Work Around: On the problem node, remove the bad RKM.conf file then run a GPFS command to regenerate the RKM.conf file. For example, run mmlscluster. Problem trigger: mount file system; access file Symptom: File system unmount Platforms affected: All Functional Area affected: encryption, admin command Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ53034
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-11-12
Closed date
2024-11-12
Last modified date
2024-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]
Document Information
Modified date:
12 November 2024