IBM Support

PH64087: ABEND S0C9 EDITING OR BROWSING LARGE TABLE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer is performing BROWSE of a DB2 table with large number
    of rows. He receives ABEND S0C9:
    
    CEE3209S The system detected a fixed-point divide exception (
    System Completion Code=0C9).
    From entry point Initialize at statement 3004 at compile unit
    offset +0000A046 at entry offset +0000A046 at
    address 21AB008E.
    
    Traceback:
      DSA   Entry       E  Offset  Statement   Load Mod  ProgramUnit
      1     CEEHDSP     +00004B12              CEEPLPKA  CEEHDSP
      2     Initialize  +000206CA  3004        FOPMEMAI  FOPEDRIV
      3     ededitad    +00001DEA  442         FOPMEMAI  FOPEDRIV
      4     mngorun     +00000A70  1126        FOPMMUNU  FOPMCALL
      5     LC_SelTbl   +000005C6  609         FOPMMUNU  FOPMTLST
      6     ExecLineCmds+0000150C  818         FOPMECMN  FOPEISPL
      7     cmispfl     +000028B2  365         FOPMECMN  FOPEISPL
      8     mntbsls     +00004432  516         FOPMMUNU  FOPMTLST
      9     PromptEditTable
                        +00002310  1147        FOPMMUNU  FOPMMENU
      10    mnprmpt     +00004934  823         FOPMMUNU  FOPMMENU
      11    main        +000040A2  909         FOPMAIN   FOPMMAIN
    

Local fix

  • Reduce the Editor Fetch Rows limit to a smaller value or
    increase the REGION size.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Optim users performing BROWSE or EDIT of     *
    *                 tables with very large number of rows or     *
    *                 working with REGIONs of limited size.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: See Error Description.                  *
    ****************************************************************
    Optim detects an out-of-storage condition due to large
    number of rows, or limited REGION size, and attempts
    recovery. An incorrectly coded test causes the abend in
    such scenarios.
    

Problem conclusion

  • Optim code will be corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH64087

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-11-11

  • Closed date

    2024-12-13

  • Last modified date

    2025-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI99443

Modules/Macros

  • FOP2RRSQ FOP9APIM FOPCFPMN FOPHSTM  FOPK00   FOPMADDE FOPMAIN
    FOPMAMAI FOPMCMAI FOPMCOLP FOPMDBMN FOPMDPRC FOPMDXTR FOPMECMN
    FOPMEMAI FOPMMCMR FOPMMJBS FOPMMUNU FOPMMUTL FOPMUXIM FOPOMN
    FOPRS10  FOPRS9   FOPT02T  FOPT29K  FOPTLPRA FOPUMCBT FOPZFMMN
    FOPZSUB
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB70 PSY UI99443

       UP24/12/17 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B70"}]

Document Information

Modified date:
02 January 2025