Troubleshooting
Problem
Trying to save a work station message queue using SAVOBJ command CPF3770 is logged.
Message ID . . . . . . : CPF3770 Severity . . . . . . . : 30
Message type . . . . . : Diagnostic
Date sent . . . . . . : 10/11/24 Time sent . . . . . . : 12:57:37
Message . . . . : No objects saved or restored for library QSYS.
Cause . . . . . : No objects were saved or restored for library QSYS at
10/11/24 12:57:37. Diagnostic messages have been sent for each error that
was detected. The objects not restored may include objects that were
partially restored and require some additional recovery action.
Recovery . . . : Press F10 or use the Display Job Log (DSPJOBLOG) command
for error information. Correct any errors and try the request again.
Message type . . . . . : Diagnostic
Date sent . . . . . . : 10/11/24 Time sent . . . . . . : 12:57:37
Message . . . . : No objects saved or restored for library QSYS.
Cause . . . . . : No objects were saved or restored for library QSYS at
10/11/24 12:57:37. Diagnostic messages have been sent for each error that
was detected. The objects not restored may include objects that were
partially restored and require some additional recovery action.
Recovery . . . : Press F10 or use the Display Job Log (DSPJOBLOG) command
for error information. Correct any errors and try the request again.
There are no other messages in the joblog.
Resolving The Problem
Workstation message queues are used for sending and receiving messages between workstation users and between workstation users and the system operator. The name of the queue is the same as the name of the workstation. The queue is created by the system when the workstation is described to the system and it is deleted when device is deleted from the system.
Since these message queues need to follow the device associated they cannot be saved individually.
When device is restored or created the work station message queue is automatically recreated.
Document Location
Worldwide
[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m0z000000cwp6AAA","label":"Save Restore"}],"ARM Case Number":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"All Versions"}]
Was this topic helpful?
Document Information
Modified date:
11 October 2024
UID
ibm17172854