IBM Support

OY09629: NEW FUNCTION SUPPORT FOR D/T3990 MODELS 1, 2, AND 3

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • NEW FUNCTION SUPPORT FOR D/T3990 MODELS 1, 2, AND 3, WHICH
    ISSUE THE RESET NOTIFICATION.
    

Local fix

Problem summary

  • THE ENHANCEMENT PROVIDES SUPPORT FOR IBM D/T3990 MODELS 1, 2,
    AND 3 WHICH ISSUE THE RESET NOTIFICATION.
    

Problem conclusion

  • THE IPL ROOT MODULE, IEAIPL00, WILL SAVE THE LAST CHANNEL USED
    MASK FROM THE FIRST SCHIB IT STORES. THIS MASK WILL BE USED BY
    IEAIPL00 TO INITIALIZE THE LOGICAL PATH MASKS FOR ALL ORBS.
    

Temporary fix

Comments

  • INSTALL THIS FIX ON ALL SYSTEMS WITH D/T3380 SYSRES DEVICES,
    WHETHER THEY ARE CURRENTLY BEHIND A D/T3990 OR NOT.
    AN IPL WITHOUT THIS LEVEL OF IPL TEXT (IEAIPL00) ON A D/T3380
    BEHIND A D/T3990 WILL RESULT IN A DISABLED WAIT STATE WAIT005.
    WHEN RUNNING THE JOB TO PUT IEAIPL00 TO SYSRES YOU MUST
    CONCATENATE IPLRECS AHEAD OF IEAIPL00.
    

APAR Information

  • APAR number

    OY09629

  • Reported component name

    5752 IPL

  • Reported component ID

    5752SC1C9

  • Reported release

    B12

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1987-10-13

  • Closed date

    1987-12-17

  • Last modified date

    1989-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UY90149 UY90150 UY90151 UY25437 UY27351 UY28356 UY28459 UY28460
    UY29285 UY31430 UY31602 UY32155 UY32321

Modules/Macros

  •    IEAIPL00
    

Fix information

  • Fixed component name

    5752 IPL

  • Fixed component ID

    5752SC1C9

Applicable component levels

  • RB12 PSY UY90149

       UP88/01/19 P F802

  • RB13 PSY UY90150

       UP88/01/19 P F802

  • RB20 PSY UY90151

       UP88/01/19 P F802

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"B12"}]

Document Information

Modified date:
04 October 2024