IBM Support

PH63477: UNUSED DYNAMIC LENGTH ITEM WITH STGOPT LEADS TO COMPILER FAILURE IGYPG5125-U IGYPG5201-U ERROR CODE "PTEXT-07"

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If a DYNAMIC length item is defined but not used, and the STGOPT
    
    option is set, the compiler fails with
    
    IGYPG5125-U The compilation was terminated due to a compiler
           error in phase id: "IGYCPGEN".
    IGYPG5201-U Internal compiler error code "PTEXT-07" occurred.
    

Local fix

  • Compile with NOSTGOPT or remove (comment out) the unused dynamic
    
    length item.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users compiling COBOL programs with the      *
    *                 STGOPT compiler option in effect, when the   *
    *                 program contains data items defined with the *
    *                 DYNAMIC LENGTH clause in the DATA DIVISION,  *
    *                 but with no references (as sending or        *
    *                 receiving operands) to those items in the    *
    *                 PROCEDURE DIVISION.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: The compiler encounters a terminating   *
    *                      (RC 16) error and halts compilation.    *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM provided PTF.                  *
    ****************************************************************
    Incorrect compiler internal processing causes a compiler crash
    with a terminating error when the STGOPT compiler option is in
    effect, and DYNAMIC LENGTH items are defined in the DATA
    DIVISION but are not referenced in the PROCEDURE DIVISION.
    

Problem conclusion

  • The compiler has been fixed. Compilations are now successful.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH63477

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-09-30

  • Closed date

    2024-10-22

  • Last modified date

    2024-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UI98832

       UP24/10/31 P F410

  • R641 PSY UI98833

       UP24/10/31 P F410

  • R642 PSY UI98834

       UP24/10/31 P F410

  • R64H PSY UI98835

       UP24/10/31 P F410

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
03 November 2024