APAR status
Closed as program error.
Error description
ACLs are not fetched to AFM cache from the home when the opened AFM control file becomes stale. AFM control file is used to fetch ACLs and EAs from the home.
Local fix
Stop and Start the AFM replication using the mmafmctl command
Problem summary
ACLs are not fetched to AFM cache from the home when the opened AFM control file becomes stale. AFM control file is used to fetch ACLs and EAs from the home.
Problem conclusion
This problem is fixed in 5.1.9.6 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale _apars.html Benefits of the solution: Fixed the code to reopen the AFM control file to fetch ACLs properly Work Around: Stop and Start the AFM replication using the mmafmctl command Problem trigger: Invalid AFM control file at the target Symptom: Unexpected results Platforms affected: All Linux OS environments Functional Area affected: AFM Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ52324
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-11
Closed date
2024-09-18
Last modified date
2024-09-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]
Document Information
Modified date:
19 September 2024