IBM Support

IJ52206: MMXCP DOES NOT COPY SPECIAL MODE BITS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The mmxcp utility does not copy the file mode bits for SUID,
    SGID, or "sticky bit".
    

Local fix

  • The chmod command can be used to set the SUID, SGID or "sticky
    bit" on any files or directories in the target directory that
    need them.
    

Problem summary

  • The mmxcp utility does not copy the file mode bits for SUID,
    SGID, or "sticky bit".
    

Problem conclusion

  • This problem is fixed in 5.1.9.6
    To see all Spectrum Scale APARs and their respective
    Fix solutions refer to page: 
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale
    _apars.html
    
    Benefits of the solution:
    Code has been added that will copy the special mode bits on
    files and directories if present.
    
    Work Around:
    The chmod command can be used to set the SUID, SGID or "sticky
    bit" on any files or directories in the target directory that
    need them.
    
    Problem trigger:
    The problem occurs when "mmxcp enable" copies a file or
    directory that has any of the special mode bits set (SUID, SGID,
    or "sticky bit").
    
    Symptom:
    Unexpected Results/Behavior
    
    Platforms affected:
    ALL Linux OS environments
    
    Functional Area affected:
    Filesets
    
    Customer Impact:
    Suggested
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ52206

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-08-28

  • Closed date

    2024-09-18

  • Last modified date

    2024-09-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]

Document Information

Modified date:
19 September 2024