APAR status
Closed as program error.
Error description
On Qlogic adapters, asynchronous logins from other devices/ hosts in the SAN fabric can consume the login table list maintained by the physical adapter driver. When this happens the error log will be filled with FCA_ERR6 errors, with "0003" and "0124" in the first line of sense data as indicated here: LABEL: FCA_ERR6 IDENTIFIER: ECCE4018 Detail Data SENSE DATA 0000 0003 0000 0124 ... The errors themselves are harmless, and the adapter will still be able to login to the fabric and storage devices. This APAR prevents the login table from being improperly filled up.
Local fix
Reboot the host where the Qlogic adapters reside in order to clear the login tables in the physical adapter driver. In a VIO configuration, that means rebooting the VIO server.
Problem summary
Similar errpt entries: LABEL: FCA_ERR6 IDENTIFIER: ECCE4018 Detail Data SENSE DATA 0000 0003 0000 0124 ... New target ports in the fabric will not be logged in after this situation.
Problem conclusion
Code fixed to avoid the issue by fixing the login entry management code.
Temporary fix
Comments
6100-09 - use AIX APAR IJ01096 6100-09 - use AIX APAR IJ01096 7100-05 - use AIX APAR IJ02640 7200-03 - use AIX APAR IJ02592
APAR Information
APAR number
IJ01096
Reported component name
VIRTUAL I/O SER
Reported component ID
5765G3400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-28
Closed date
2017-12-08
Last modified date
2018-10-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
VIRTUAL I/O SER
Fixed component ID
5765G3400
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSAVPM","label":"PowerVM VIOS Standard Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
06 August 2024