IBM Support

PH55062: ABENDS5C6-00C5101D,C=MQ900.920.CFM - CSQECLOS,M=CSQGFRCV,LOC=CSQELPLM.CSQECLOS+00003670

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After investigation of this problem, it appears there are two
    copies of the queue, where we suspect that the MQSH has been
    overwritten. The abend occurred during shared queue close
    processing where we expected that the STRB and SQVT control
    blocks should have been orphaned following us losing connection
    to the structure, however this orphan processing didn't appear
    to have been driven in its entirety, ultimately resulting in
    the abend following a consistency check.
    
    Unfortunately we have been unable to identify the root cause of
    this problem, although we suspect that the MQSH being
    overwritten is likely to have caused this behaviour. However,
    we cannot see the MQSH being overwritten in the dump. For this
    reason, we would like to investigate how we could improve our
    diagnostics in this area to help us identify this problem at
    the time closer to which the MQSH may have been overwritten if
    it occurs again in the future.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM MQ for z/OS Version 9       *
    *                 Release 2 Modification 0,                    *
    *                 Release 3 Modification 0 and                 *
    *                 Release 4 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: CSQECLOS abends with 5C6-00C5101D and a *
    *                      follow on 5C6-00C510AD abend is issued  *
    *                      as the initial abend was on a structure *
    *                      task. This results in Queue Manager     *
    *                      termination.                            *
    ****************************************************************
    Two copies of the same queue exist leading to CSQECLOS abending
    with 5C6-00C5101D and a follow on 5C6-00C510AD as part of a
    consistency check. As the initial abend was on a structure
    task the Queue Manager terminates.
    
    The reason for the existence of the duplicate queue is currently
    unknown.
    

Problem conclusion

  • New diagnostic code has been added to capture additional
    documentation to aid in the diagnosis of understanding why the
    duplicate queue exists. By default this new diagnostic code is
    disabled, please contact IBM support to enable it.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH55062

  • Reported component name

    IBM MQ Z/OS V9

  • Reported component ID

    5655MQ900

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-06-09

  • Closed date

    2024-07-24

  • Last modified date

    2024-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI97770 UI97771 UI97772

Modules/Macros

  • CSQ7CBZ2 CSQIESEL CSQIRECP
    

Fix information

  • Fixed component name

    IBM MQ Z/OS V9

  • Fixed component ID

    5655MQ900

Applicable component levels

  • R200 PSY UI97772

       UP24/09/25 P F409

  • R300 PSY UI97771

       UP24/09/25 P F409

  • R400 PSY UI97770

       UP24/09/25 P F409

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"200","Line of Business":{"code":"LOB67","label":"IT Automation \u0026 App Modernization"}}]

Document Information

Modified date: