Release Notes
Abstract
This firmware update (v10.0.0) provided by IBM is intended for xSeries firmware updates on your IBM® Security QRadar® M6 appliances. This update is intended for M6 1U and 2U form factor QRadar appliances where administrators want to update appliances with a bootable USB drive to complete an on prem firmware update.
Content
Important: Select a tab to read each step of the firmware procedure.
Creating your USB flash drive for the firmware update requires a Windows™ host and the administrator must be on site with the appliance. The firmware update can take up to 60 minutes complete per appliance and the administrator is required to reboot the appliance after the firmware installation completes. The firmware upgrade procedures are intended for scheduled maintenance hours. If your data center does not allow USB keys, instructions and a download are available for administrators to install firmware remotely with the XClarity interface. For information about firmware updates over XClarity interfaces, see https://www.ibm.com/support/pages/node/6998777.
This firmware update applies to the following IBM Security QRadar M6 (1U and 2U form factor) appliance types:
Table 1: List of QRadar appliances the M6 firmware 10.0.0 can update.
To create a bootable USB key, you must have access to the following items:
Part 1: About the M6 firmware 10.0.0 update
Creating your USB flash drive for the firmware update requires a Windows™ host and the administrator must be on site with the appliance. The firmware update can take up to 60 minutes complete per appliance and the administrator is required to reboot the appliance after the firmware installation completes. The firmware upgrade procedures are intended for scheduled maintenance hours. If your data center does not allow USB keys, instructions and a download are available for administrators to install firmware remotely with the XClarity interface. For information about firmware updates over XClarity interfaces, see https://www.ibm.com/support/pages/node/6998777.
Supported appliances, types, and model information
This firmware update applies to the following IBM Security QRadar M6 (1U and 2U form factor) appliance types:
Hardware | Details |
Appliance and machine type model (MTM) |
1U
IBM QRadar Core Appliance XX05 G4 (4563-Q3E)
IBM QRadar Event/QFlow Collector Appliance 1501/1201 G4 (4563-Q5D)
IBM QRadar Network Insights Appliance 1901 G2 (4563-F8Y) IBM QRadar Network Insights Appliance 1910 G2 (4563-F7Y)
IBM QRadar Core Appliance XX48 G2 (4563-Q5B) 2U IBM QRadar Network Insights Appliance 1920 G2 (4563-F5F) IBM QRadar Incident Forensics Appliance G4 (4563-F3A) IBM QRadar Core Appliance XX29 G2 (4563-Q4A)
IBM QRadar Network Packet Capture Appliance G2 (4563-F3C) IBM QRadar Network Insights 1940 (4563-F6G) |
Server Type | M6 |
Server Machine Type | SR630 / M6 1U SR650 / M6 2U |
Important file changes and prerequisites in this firmware update
Administrators must ensure that their M6 appliance includes the minimum version outlined in the Prerequisite version column. If your M6 appliance does not meet the prerequisite versions outlined in the table, the administrator must contact IBM QRadar Support to discuss a custom upgrade path for your M6 appliance.
Table 3: Security issues resolved in the M6 firmware update 10.0.0.
Update: Depending on your initial firmware version, you might be required to meet a new UEFI prerequisite. If your current firmware does not have UEFI 3.0.0 and XCC 5.40 installed, which is required to upgrade your appliance firmware to V7.1.0, you can install the M6 V5.0.0 firmware, then upgrade to V10.0.0.
Table 2: Firmware versions and any prerequisite for each component are provided in this table.
Component | Prerequisite version | Version in this update | File name |
UEFI/BIOS |
Note: Installing M6 V5.0.0 or later meets both the UEFI and XCC requirements before you attempt to upgrade to M6 7.1.0 firmware.
|
ive182m-4.11 | lnvgy_fw_uefi_ive182m-4.11_anyos_32-64.uxz |
XCC | None |
cdo3b2h-9.80 | oem_fw_xcc_cdo3b2h-9.80_anyos_noarch.uxz |
LXPM | None | pdl144d-2.09 | lnvgy_fw_lxpm_pdl144d-2.09_anyos_noarch.uxz |
RAID controller | None | 530-51.20.0-4374-0 930-51.22.0-4634-2 |
lnvgy_fw_raid_mr3.5.530-51.20.0-4374-0_linux_x86-64.bin lnvgy_fw_raid_mr3.5.930-51.22.0-4634-2_linux_x86-64.bin |
HDD | None | 1.39.11-0 | lnvgy_fw_drives_all-1.39.11-0_linux_x86-64.bin |
PCi and LOM adapters | None | 9.2-6.2-1.3357.0-2 | intc-lnvgy_fw_nic_net-9.2-6.2-1.3357.0-2_linux_x86-64.bin |
Emulex | None | 35-14.0.376.28-4 | elx-lnvgy_fw_fc_lp.35-14.0.376.28-4_linux_x86-64.bin |
NOTES
- A number of hard disk drives can be installed in this appliance. The HDD update tool examines the hard disk drives that are present and selects the latest firmware version that is available for your drive.
- The base system pack might contain other firmware packages that are not present in QRadar appliances. Firmware updates from the base system pack can be listed when the tool compares available firmware to the hardware in the appliance and display a status of "undetected".
- For general firmware questions and information, see our FAQ page at http://ibm.biz/qradarfirmware.
Security issues resolved in this firmware update
The table lists the software versions and CVEs addressed in the firmware release.
Component | File name | Updates |
UEFI/BIOS | nvgy_fw_uefi_ive182m-4.11_anyos_32-64.uxz |
Resolved CVEs
CVE-2022-32231, CVE-2022-43505 Enhancements
Fixes
|
XCC | oem_fw_xcc_cdo3b2h-9.80_anyos_noarch.uxz |
Resolved CVEs
CVE-2015-3414, CVE-2015-3415, CVE-2015-3416, CVE-2016-6153, CVE-2017-3735, CVE-2017-3736, CVE-2017-3737, CVE-2017-3738, CVE-2017-5130, CVE-2017-6451, CVE-2017-6452, CVE-2017-6455, CVE-2017-6458, CVE-2017-6459, CVE-2017-6460, CVE-2017-6462, CVE-2017-6463, CVE-2017-6464, CVE-2017-7407, CVE-2017-8816, CVE-2017-8817, CVE-2017-10989, CVE-2017-12799, CVE-2017-12967, CVE-2017-13710, CVE-2017-14129, CVE-2017-14130, CVE-2017-14333, CVE-2017-14529, CVE-2017-14930, CVE-2017-14932, CVE-2017-14933, CVE-2017-14934, CVE-2017-14938, CVE-2017-14939, CVE-2017-14940, CVE-2017-14974, CVE-2017-15020, CVE-2017-15021, CVE-2017-15022, CVE-2017-15023, CVE-2017-15024, CVE-2017-15025, CVE-2017-15225, CVE-2017-15938, CVE-2017-15939, CVE-2017-15996, CVE-2017-16544, CVE-2017-16931, CVE-2017-16932, CVE-2017-17484, CVE-2017-1000100, CVE-2017-1000101, CVE-2017-1000254, CVE-2017-1000257, CVE-2017-1000494, CVE-2018-6872, CVE-2018-1000005, CVE-2018-1000007, CVE-2018-1000120, CVE-2018-1000121, CVE-2018-1000122 |
LXPM | lnvgy_fw_lxpm_pdl144d-2.09_anyos_noarch.uxz | None |
RAID controller | lnvgy_fw_raid_mr3.5.530-51.20.0-4374-0_linux_x86-64.bin lnvgy_fw_raid_mr3.5.930-51.22.0-4634-2_linux_x86-64.bin |
None |
HDD | lnvgy_fw_drives_all-1.39.11-0_linux_x86-64.bin | None |
PCi and LOM adapters | intc-lnvgy_fw_nic_net-9.2-6.2-1.3357.0-2_linux_x86-64.bin | None |
Emulex | elx-lnvgy_fw_fc_lp.35-14.0.376.28-4_linux_x86-64.bin | None |
Part 2: Requirements to create a bootable USB drive
To create a bootable USB key, you must have access to the following items:
- An 8 GB or larger USB flash drive.
- Entitlement for IBM Fix Central is required download firmware for QRadar appliances.
- A workstation or laptop running one the following operating systems:
- Windows™ 10
- Windows™ 7
- Windows™ Server 2008R2
- Windows™ Server 20016
NOTE: Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.
Creating the bootable USB drive
- Download the QRadar M6 appliance firmware from IBM Fix Central for QRadar 7.5.x: IBM Fix Central M6 firmware 10.0.0 IMG download
Note: Administrators can download 7.5.x software for any QRadar version as firmware downloads are identical for QRadar 7.4.x or 7.5.x on IBM Fix Central. - Download the Rufus Bootable USB Tool.
- Insert the USB flash drive into a USB port on your Windows™ laptop or workstation.
- Open Rufus and configure the properties.
Parameter Value Device Select your USB drive Boot Selection Select Qradar_IMG_M6_1U_SR630_7X02_2U_SR650_7X06_10_0_0.img Partition scheme MBR (Default) Target system BIOS (or UEFI-CSM) (Default) File system FAT32 (Default) Cluster size This value defaults to the best option based on size of the USB drive.
For example, - Click Start. The image is loaded on the USB drive.
- After the installation finishes, safely eject the USB flash drive from your computer.
Results
The bootable drive is ready to be used to install firmware on the M6 appliance.
Part 3. Installing the Firmware on the QRadar M6 appliance
The instructions are intended for M6 appliances that are not configured as HA (high-availability) pairs. If your appliance is in a HA pair, you must use the High-Availability update instructions found here: http://www.ibm.com/support/docview.wss?uid=swg27047121#HA .Booting from the USB Drive
- Insert the USB drive that has the bootable image into the QRadar appliance.
IMPORTANT: Do not remove the USB flash drive until the IBM ToolsCenter completes the firmware installation. - From the terminal or the KVM switch for the appliance, log in with root user credentials.
- From the command prompt, type: reboot
- As the appliance reboots, press F12.
- From the Boot Devices Manager, verify the Legacy Mode check box is clear (NOT selected).
- Locate your USB drive in the Boot Devices Menu and press Enter.
- In the Update Settings menu, verify all check boxes are clear (not selected) and click Next.
- In the Update Comparison menu, click Begin.
- The IBM UpdateXpress System Pack Installer compares the current package with the installed firmware.
- Verify all check boxes are selected where new firmware versions are available and click Next.
IMPORTANT: Administrators must review the New Version column and confirm the firmware update is selected (checked). Issues were reported where firmware changes were not installed in prior releases.
Note: The image provided is an example only. Firmware versions during your update will differ from the example image. - Wait for the firmware updates to load.
- Click Begin Update to install the firmware.
NOTE: Administrators might be prompted with a confirmation dialogue and need to click Next to continue. - Verify that all updates complete successfully and click Next.
- If you experienced any errors, click Save Log or click Finish to exit after a successful installation.
- The appliance must reboot to complete the firmware installation.
Results
The appliance reboots and is available for use in the QRadar deployment. If you experience any installation issues, you can contact QRadar Support for assistance and open a software support case for your appliance. The support representative can onsite request the firmware logs for review to determine the root cause of the issue or if replacement hardware is required. If the issue is hardware-related, the support representative can change the case type and involve the proper teams to schedule replacement parts.
[{"Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSBQAC","label":"IBM Security QRadar SIEM"},"ARM Category":[{"code":"a8m0z000000cwtcAAA","label":"Hardware"}],"ARM Case Number":"","Platform":[{"code":"PF016","label":"Linux"}],"Version":"All Version(s)"}]
Was this topic helpful?
Document Information
Modified date:
13 June 2024
UID
ibm17157406