A fix is available
APAR status
Closed as program error.
Error description
A data set locked by Change Tracker can be updated by SMP/E APPLY.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM z/OS Change Tracker. * **************************************************************** * PROBLEM DESCRIPTION: 1. A member in a PDS or PDS/E locked by * * z/OS Change Tracker can be replaced * * by SMP/E APPLY. * * 2. CSAVE fails for a checked out * * member. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 1. A data set member protected by z/OS Change Tracker with LOCK=Y can be replaced by the SMP/E APPLY process. 2. When using CSAVE to save a checked out member it fails with a 'CSAVE Data is not saved' or 'STOW failed' message.
Problem conclusion
1. A data set member protected by z/OS Change Tracker with LOCK=Y will now be blocked for update or replacement by the SMP/E APPLY process. 2. Checked out members can now be saved using CSAVE.
Temporary fix
Comments
APAR Information
APAR number
PH61759
Reported component name
Z/OS CHANGE TRA
Reported component ID
5752SCCYG
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-10
Closed date
2024-07-08
Last modified date
2024-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI97610
Modules/Macros
CYGCSAVE CYGMLPOP CYGMOD CYGQCTRK
Fix information
Fixed component name
Z/OS CHANGE TRA
Fixed component ID
5752SCCYG
Applicable component levels
R100 PSY UI97610
UP24/07/25 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.