Troubleshooting
Problem
When installing IBM System Automation for z/OS V4R1, I have experienced issues with the APPLY CHECK step.
The reports indicate ERROR HOLDs for ++APARs fixes AA54882 and AA55018 (associated with APARs OA54882 and OA55018).
Reviewing the APARs , I see that HIPER APAR OA54882 is fixed by PTF UA95311 and HIPER APAR OA55018 is fixed by PTF UA95433.
Also, PTF UA95311 is superseded by PTF UA95433.
Both UA95311 and UA95433 have been received.
In order to get the APPLY CHECK to complete with a RC=4 instead of RC=12, I selected BYPASS(HOLDFIXCAT).
Symptom
When including all HIPER maintenance during a new install of System Automation for z/OS 4.1, the following messages may be issued:
GIM35901I ERROR HOLD AA52307 WAS NOT RESOLVED.
GIM35901I ERROR HOLD AA52473 WAS NOT RESOLVED.
GIM35901I ERROR HOLD AA54882 WAS NOT RESOLVED.
GIM35901I ERROR HOLD AA55018 WAS NOT RESOLVED.
Cause
PTF packaging
Environment
IBM Tivoli System Automation for z/OS 4.1
Diagnosing The Problem
SMP/E Apply Listing
Resolving The Problem
AI (Additional Information) flags and comments have been added to PTF UA91779 (HIPER APAR OA52307), PTF UA92028 (HIPER APAR OA52473), PTF UA95311 (HIPER APAR OA54882), and PTF UA95433 (HIPER APAR OA55018).
Problem circumvention:
BYPASS(HOLDERROR(AAnnnnn,AAnnnnn)) where nnnnn is an APAR number
(Example: AA54882) documented in the GIM35901I messages.
or
BYPASS(HOLDSYSTEM,HOLDFIXCAT,HOLDCLASS(HIPER))
can be used safely to overcome the errors.
IBM System Automation for z/OS 4.1 PSP (Preventive Service Planning) bucket upgrade HWRE410 Subset HWRE410 has been updated.
Related Information
Product Synonym
SA SA/zOS Sys Auto
Was this topic helpful?
Document Information
Modified date:
12 June 2019
UID