APAR status
Closed as program error.
Error description
Ensure that the dentry type and inode type are in sync. ááá ááá Fix for: metadata corruption on one node ááá áThe issue happens because d_can_lookup() call fails for the dentry in áquestion. As seen from the dentry flags the dentry type is flagged as a normal file while the inode shows that it is directory. This change patches the gpfs with a failsafe piece of code that detects áthis state, drops the dentry and causes a lookup to happen again. ááá
Local fix
Problem summary
Metadata corruption on one node with folders not being correctly visible. Cannot cd into directory on one node.
Problem conclusion
This change adds a failsafe piece of code that detects the erroneous state and causes a lookup to happen again.
Temporary fix
Comments
APAR Information
APAR number
IJ51031
Reported component name
SPEC SCALE DME
Reported component ID
5737F34AP
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-05-01
Closed date
2024-05-22
Last modified date
2024-07-22