APAR status
Closed as program error.
Error description
HIPAA compliance check map execution performance impact when SNIP Type 5 checking / validation is enabled. Example: HIPAA 837I PACDR data file with 50K transactions with one claim per transaction takes more than 2 hours to complete with SNIP Type 5 validation turned on and about 7 minutes to complete with SNIP Type 5 validation turned off.
Local fix
ITXCQ - ITX00062320 MG / MG Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: Performance issue processing large number of transactions when type 5 validation enabled. Platforms Affected: ALL
Problem conclusion
Removed extraneous full type 2 checking if passthrough was successful and type 5 enabled. Also improved efficiency of pattern match rules. Applies to: Healthcare Pack HIPAA 10.2.1, 10.2.2. Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/ transformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH59848
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
B00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-16
Closed date
2024-04-25
Last modified date
2024-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
xxxx xxxx
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]
Document Information
Modified date:
11 May 2024