  • In case you are using a "old" mksysb image (old means
    more
    than 3 months) to perform the viosupgrade, it is possible
    that padmin user faces an expired password issue when
    rebooting on the updated version "4.1" of the OS.
    At login after reboot, login fails with :
    From console :
    login: padmin
    padmin's Password:
    [compat]: 3004-327 Your password has been expired for
    too\
                       long.
    3004-321 Please see the system administrator to change
              your password.
    
    From ssh :
    padmin@vios2's password:
    Permission denied, please try again.
    

Local fix

  • # viosvrcmd -m <Managed System Name> --id <VIOS lpar id>
    \
      -c "chuser -attr maxage=0 padmin"
    # viosvrcmd -m <Managed System Name> --id <VIOS lpar id>
    \
      -c "chuser -attr maxexpired=-1 padmin"
    

Problem summary

  • Fixed in next release
    

Problem conclusion

Temporary fix

Comments

  • This APAR is being closed FIN. This means that a solution to
    this APAR is expected to be delivered from IBM in a release
    (if any) to be available within the next 24 months.
    

APAR Information

  • APAR number

    IJ50453

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED FIN

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-03-13

  • Closed date

    2024-03-13

  • Last modified date

    2024-03-13

  • APAR is sysrouted FROM one or more of the following:

    IJ50326

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
04 April 2024