Error description
When a thread is flushing the file metadata of the ACL file to disk, there?s a small window that a deadlock can occur when a different thread tries to get a Windows security descriptor, as getting the security descriptor requires reading the ACL file.
Local fix
- Avoid setting and getting Windows Security Descriptor at the same time - Restart GPFS
Problem summary
When a thread is flushing the file metadata of the ACL file to disk, there?s a small window that a deadlock can occur when a different thread tries to get a Windows security descriptor, as getting the security descriptor requires reading the ACL file.
Problem conclusion
This problem is fixed in 5.1.9.3 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: Fixed the code so that the deadlock is avoided in this situation. Work Around: - Avoid setting and getting Windows Security Descriptor at the same time - Restart GPFS Problem trigger: - Make changes to Windows Security Descriptors/ACLs and ensure the changes go to the disk - Retrieve the Windows Security Descriptor of inodes Symptom: Hang/Deadlock/Unresponsiveness/Long Waiters Platforms affected: Windows Functional Area affected: All Scale Users Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ50321
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-29
Closed date
2024-03-13
Last modified date
2024-03-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Line of Business":{"code":"LOB69","label":"Storage TPS"}}]
Document Information
Modified date:
04 April 2024