A fix is available
APAR status
Closed as program error.
Error description
This APAR includes a change that when reading output from Python will replace any characters with a space that are outside the UTF-8 code point. These characters do not correspond to UTF-8 requirements and are sanitized so that the resulting log can be printed. This will resolve any UnicodeDecodeError that would previously had occurred during job processing in Python.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Z Open Automation Utilities * * (ZOAU) version 1.2.x * **************************************************************** * PROBLEM DESCRIPTION: In the ZOAU Python language pack, * * calling ZOAU APIs may result in output * * that contains unprintable characters. * * These can result from job output, * * datasets, command responses, or log * * output. These characters will cause a * * UnicodeDecodeError to be raised in the * * Python script during conversion to a * * string. * * * * This APAR detects these unprintable * * characters and converts them to spaces * * so an exception is no longer raised. * **************************************************************** * RECOMMENDATION: APPLY APAR/PTF. Follow instructions in PTF * * HOLDs. * **************************************************************** This is a maintenance release with a single bug fix. It is a full replacement for all prior versions of ZOAU 1.2.x.
Problem conclusion
*****
Temporary fix
Comments
APAR Information
APAR number
PH60060
Reported component name
Z OPEN AUTO UTL
Reported component ID
5724T0753
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-27
Closed date
2024-03-19
Last modified date
2024-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI96141
Modules/Macros
BGYPX001 BGYPX002 BGYPX003 BGYPX004 BGYPX005 BGYPX006 BGYPX007 BGYPX008 BGYPX009 BGYPX010 BGYPX011 BGYPX012 BGYPX013 BGYPX014 BGYSHZOA
Fix information
Fixed component name
Z OPEN AUTO UTL
Fixed component ID
5724T0753
Applicable component levels
R120 PSY UI96141
UP24/03/21 P F403
Fix is available