A fix is available
APAR status
Closed as program error.
Error description
If an external routine, e.g. an SMS one called during the Db2 HPU process, uses ACCESS REGISTERS without restoring them before exiting, HPU terminates with an ABENDU1234. Db2 HPU should be made robust to the impact of such an incorrect handling of ACCESS REGISTERS by external routines, by saving the ACCESS REGISTER before calling dataset open and close service.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 High Performance Unload for * * z/OS * **************************************************************** * PROBLEM DESCRIPTION: If an external routine, e.g. an SMS * * one called during the Db2 HPU process, * * uses ACCESS REGISTERS without * * restoring them before exiting, * * HPU terminates with an ABENDU1234. Db2 * * HPU should be made robust to the * * impact of such an incorrect handling * * of ACCESS REGISTERS by external * * routines, by saving the ACCESS * * REGISTER before calling dataset open * * and close service. * * * * Local fix: none unless the external * * routine that does not restore the * * ACCESS REGISTERS after use can be * * determined and fixed. * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** ABENDU1234 if ACCESS REGISTERS unduly updated by external routine
Problem conclusion
Code has been changed to fix this problem
Temporary fix
Comments
APAR Information
APAR number
PH60075
Reported component name
DB2 HI PERF UNL
Reported component ID
5697F4400
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-28
Closed date
2024-03-28
Last modified date
2024-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI96299
Modules/Macros
INZUTILK
Fix information
Fixed component name
DB2 HI PERF UNL
Fixed component ID
5697F4400
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: