APAR status
Closed as program error.
Error description
Compliance check is failing valid 277CA file citing the reason of maximum usage of REF segment at 2220D loop but as per TR3 notes two REF segments are allowed. Only one REF segment is allowed in the base X12 standard. TYPE 2: error Error Code: 5 {Segment Exceeds Maximum Use} Error Description: ERROR
Local fix
ITXCQ - ITX00062107 MG / MG Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: Compliance check fails with 2 valid REF segments in the 2220D loop in the 277CA (5010X214). Platforms Affected: ALL
Problem conclusion
X12 5010 Base Standards and TR3 for 5010X214 conflict on number of REFs allowed in the 2220D loop for 5010X214, so structure file was shipped to match the X12 limit. This has been updated to allow 2 REF segments per the TR3. Applies to: Healthcare Pack HIPAA 10.2.1. Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/t ransformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH57131
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-22
Closed date
2023-12-20
Last modified date
2023-12-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
28 December 2023