Error description

  • Snapshot creation cannot be done due to a background file
    deletion is running into infinite loop on a corrupted
    compression file.
    

Local fix

Problem summary

  • Snapshot creation cannot be done due to a background file
    deletion is running into infinite loop on a corrupted
    compression file.
    

Problem conclusion

  • This problem is fixed in 5.1.2.15
    To see all Spectrum Scale APARs and their respective
    Fix solutions refer to page:
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_
    apars.html
    
    Benefits of the solution:
    Fixed the code issue not abort the decompression on a corrupted
    compression file, then the snapshot creation or other operations
    interlocking with the being destroyed file can proceed.
    
    Work around:
    None
    
    Problem trigger:
    Corrupted compression file.
    
    Symptom:
    deadlock
    
    Platforms affected:
    All Operating Systems
    
    Functional Area affected:
    Compression
    
    Customer Impact:
    Critical
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ49472

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    512

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-12-07

  • Closed date

    2023-12-07

  • Last modified date

    2023-12-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
08 December 2023