Error description
RST link 119-120 failed from IMS1 after IMS2 /ERE. Messages from STLABA8: STLABA8 15125 09:12:35.25 INTERNAL 00000210 S IMS140YC,IMSID=2 15125 09:12:54.56 YINCHO 00000210 R 88,/ERE. STLABA8 15125 09:24:14.77 YINCHO$ 00000210 @TRA SET ON LINK 119-120 MODULE DFS3211I 9:24:59 MISMATCH RESYNCH CONDITION LINK 0119 THIS SYSTEM IS PRIMARY IMS2 DFS000I STSN: 40400000001F RESP: 040800000000 IMS2 DFS3211I 9:24:59 MISMATCH RESYNCH CONDITION LINK 0120 THIS SYSTEM IS PRIMARY IMS2 DFS000I STSN: 404000000031 RESP: 040800000000 IMS2 DFS3212I 9:24:59 MISMATCH RESYNCH CONDITION LINK 0119 UNACCEPTABLE TO PRIMAR IMS2 DFS000I Y IMS2 DFS3212I 9:24:59 MISMATCH RESYNCH CONDITION LINK 0120 UNACCEPTABLE TO PRIMAR IMS2 DFS000I Y IMS2 DFS3239 09:24:59 CLSDST/TRMSESS ISSUED LINK 119 IMS2 DFS3239 09:24:59 CLSDST/TRMSESS ISSUED LINK 120 IMS2 Where: DFS3211I is issued with Primary outbout action code=40 " inbout action code =40 " outbout seq # =0000 " inbout seq# =0000 Secondary outbout action coe =04 inbout action code =08 outbout seq # =0000 inbout seq# =0000
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All IMS V14 users using Dynamic MSC. * **************************************************************** * PROBLEM DESCRIPTION: * * /RST LINK command fails with DFS3211I * * after an IMS ERE. * **************************************************************** * RECOMMENDATION: * * INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** After an IMS emergency restart, a /RST LINK command fails with DFS3211I due to the sequence number mismatch. During an ERE, the restart logic DFSCRPD0 processes a x'35' record for a non-recoverable message. The QLNQF3PC flag is set causing DFSCRPD0 to invalidly update the CRBINPUT with CRBLASTI which leads to the resynch mismatch problem.
Problem conclusion
DFSCRPD0 has been enhanced to check for CRBHENQ when processing the x'35' log record with QLNQF3PC for MSC links. If CRBHENQ is set, it implies that this x'35' record is preceeded by a x'66' pre-enq record, then update CRBINPUT with CRBLASTI. Otherwise, skip updating CRBINPUT. DFSCMSV0 and DFSCMSZ0 have been modified to initialize CRBHENQ properly for non-recoverable and recoverable messages. DFSCMSF0 has been modified to correct the CTT access.
Temporary fix
Comments
APAR Information
APAR number
PI42432
Reported component name
IMS V14
Reported component ID
5635A0500
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-05
Closed date
2015-07-22
Last modified date
2015-10-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI29641
Modules/Macros
DFSCMSV0 DFSCMSF0 DFSCRPD0 DFSCMSZ0
Fix information
Fixed component name
IMS V14
Fixed component ID
5635A0500
Applicable component levels
R402 PSY UI29641
UP15/07/24 P F507