PH58092: THE ONLINE POINTER CHECKER ( OPC ) UTILITY WILL DETECT AN SDEP CI WHEN FLAG DBLKF1SDEP_FULL IS NOT SET

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This enhancement enables the Online Pointer Checker utility to
    detect an SDEP CI when the DBLKF1SDEP_FULL flag is not set.
    It will also provide an option to specify the severity level of
    the newly outputted notification messages.
    
    This enhancement is being implemented as a result of IDEA
    requirement IMSFPSP-I-6.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Online Pointer Checker of HPFPU *
    *                 Fast Path Online Tools in Fast Path Solution *
    *                 Pack Version 2 Release 1                     *
    *                 (FMID: HAHQ210).                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: Online Pointer Checker (OPC) utility    *
    *                      supports a new SDEPFULL_OFF_MSGLVL      *
    *                      keyword to control the severity level   *
    *                      of the message, which is issued when    *
    *                      there is an SDEP CI that does not have  *
    *                      the DBLKF1SDEP_FULL flag turned on.     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR enables OPC to detect SDEP CIs between logical begin
    and logical end that does not have the DBLKF1SDEP_FULL flag
    turned on.
    A new keyword SDEPFULL_OFF_MSGLVL is provided to control the
    severity level of the message.
    If SDEPFULL_OFF_MSGLVL=INFORMATIONAL is specified, an
    information message is issued when an SDEP CI that does not
    have the DBLKF1SDEP_FULL flag turned on is detected.
    If SDEPFULL_OFF_MSGLVL=NOMSG(default) is specified,
    no message is issued when an SDEP CI that does not have the
    DBLKF1SDEP_FULL flag turned on is detected.
    If SDEP_PTRIOVF_MSGLVL=WARNING is specified, a warning
    message is issued when an SDEP CI that does not have the
    DBLKF1SDEP_FULL flag turned on is detected.
    
    This enhancement is being implemented as a result of IDEA
    requirement IMSFPSP-I-6.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS Fast Path Solution Pack for z/OS Version 2 Release 1
    IMS High Performance Fast Path Utilities User's Guide
    (SC27-9536)
    Refer to topic "What's new in IMS HP Fast Path Utilities"
    (https://www.ibm.com/docs/en/SSS8RM_2.1.0/fpxhua/topics/
    fpxovv-whatsnew.html) in IBM Documentation for doc changes
    associated with this APAR.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH58092

  • Reported component name

    IMS FP SOLUTION

  • Reported component ID

    5655W1400

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2023-11-09

  • Closed date

    2024-02-27

  • Last modified date

    2024-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI95826

Modules/Macros

  • FPXAOPC0 FPXASDP0 FPXAUCS0 FPXMBLK0 FPXMSG00 FPXPDRV5 FPXPDRVE
    FPXUCA00 FPXUCKE0 FPXUCPR0 FPXUIOB0 FPXXRGP0
    

Publications Referenced
SC27953618    

Fix information

  • Fixed component name

    IMS FP SOLUTION

  • Fixed component ID

    5655W1400

Applicable component levels

  • R210 PSY UI95826

       UP24/02/29 P F402  