A fix is available
APAR status
Closed as program error.
Error description
When DB2 configuration keyword TRUNCATE is configured as RESTRICT_TRIGGERS, IIDR CDC for z/OS replicates source TRUNCATE IMMEDIATE operation as a CLEAR message. However, if the TRUNCATE IMMEDIATE operation somehow fails before it can succeed, CDC would end the replication after reporting message CHC0330E and CHC1522E.
Local fix
Configure the keyword TRUNCATE to be OFF.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS * **************************************************************** * PROBLEM DESCRIPTION: When TRUNCATE keyword in the CHCDBMxx * * member of the configuration dataset is * * configured as RESTRICT_TRIGGERS, IIDR * * CDC for z/OS replicates source TRUNCATE * * IMMEDIATE operation as a CLEAR message. * * However, if the TRUNCATE IMMEDIATE * * operation somehow fails before it can * * succeed, CDC ends the replication after * * reporting message CHC0330E and CHC1522E * **************************************************************** The logic to handle TRUNCATE IMMDEIATE operation does not process the failure of TRUNCATE IMMEDIATE properly, this causes message CHC0330E and CHC1522E to be issued and replication to fail.
Problem conclusion
The logic to handle TRUNCATE IMMDEIATE operation has been improved.
Temporary fix
Comments
APAR Information
APAR number
PH53720
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-04-05
Closed date
2023-11-20
Last modified date
2023-12-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI94543
Modules/Macros
CHCDSCPF CHCSTGSP
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI94543
UP23/12/06 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 December 2023