D-mode IPL from tape fails with B6005121 on IBM i

Flashes (Alerts)


Abstract

When the PTF for MA50161 is PERM applied, and the PTF for MA50018 is not PERM applied, and a SAVSYS is taken, a D-mode IPL from that tape will fail with B6005121.

Content

A code defect has been recently discovered.  There is a set of fairly recent tape PTFs for the following APARs:

MA50161 - LIC-MEDIA-TAPE-INCORROUT FIX TAPE LIBRARY SERIAL NUMBERS
https://www.ibm.com/support/pages/apar/MA50161

R720 MF70936
R730 MF70937
R740 MF70938
R750 MF70939

MA50018 - LIC-MEDIA-TAPE-INCORROUT-TAPE-D/T3555 INVALID SERIAL NUMBERS
https://www.ibm.com/support/pages/apar/MA50018

R720 MF70984
R730 MF70985
R740 MF70986
R750 MF70987

Some of the code supplied by the PTFs for MA50161 does a check for some of the code supplied by the PTFs in MA50018.  This works fine while the system is up and running beyond a certain point, but does not work during the D-mode IPL. So the problem can be described as:

Problem Description:  When the PTF for MA50161 is PERM applied and the PTF for MA50018 is not PERM applied, and a SAVSYS is taken, a D-mode IPL from that tape will fail with B6005121.

The PTFs for MA50161 are marked defective and the superseding PTFs are HIPER.  The fixing PTFs were approved on the afternoon of 8/8/2023.

APAR MA50290 has been created for this issue:
MA50290 - LIC-MEDIA-TAPE-SRCB6005221
https://www.ibm.com/support/pages/apar/MA50290
The fixing PTFs are:
R750 MF71224
R740 MF71223
R730 MF71222
R720 MF71221

Circumventions:

  • Perform the D-mode IPL from IBM-supplied installation media. Tape can then be selected as the alternate installation device.
  • Perform the D-mode IPL from a SAVSYS tape that does not have the PTF for MA50161 PERM applied.
  • PERM apply the PTF for MA50018 and take another SAVSYS and perform the D-mode IPL from the new SAVSYS.

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m0z0000000CMjAAM","label":"Tape"}],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0;7.3.0;7.4.0;7.5.0"}]