IBM Support

PH53466: BACKUP FILE NOT CREATED FOR MAP INPUT OR OUTPUT CARD WHEN USING RELATIVE PATH AND RUNNING THE MAP FROM ACE OR ITX API

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • This applies to ITX 10.1.1.1 and 10.1.2 on Linux with ACE 12.0.7
    
    In a message flow, if you configure an ITX map to enable the
    generation of an input backup card and the directory is set to
    be relative, upon flow execution, the input backup file is not
    generated.
    
    If the path is absolute, it is generated.  This works fine with
    a relative path on Windows.  This also works on Linux if you use
    the Command Server.
    
    In the service trace you see the following entries:
    relative: <BackupDirectoryCustomValue id="207"
    type="text">..</BackupDirectoryCustomValue>
    
    absolute: <BackupDirectoryCustomValue id="207"
    type="text">/full/path</BackupDirectoryCustomValue>
    

Local fix

  • ITXCQ - ITX00061857
    EY / TR
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender users using ITX maps that have
    relative backup file paths.
    
    Problem Description:
    An input backup file is not created from an ACE msgflow when the
    directory has a relative path
    
    Platforms Affected:
    All
    

Problem conclusion

  • Fixed resolving relative paths so they are based on the map
    location.
    
    Applies to:
    10.0.0.0, 10.0.3.1, 10.1.0.2, 10.1.1.1, 10.1.2.0
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Release Notes page:
    https://www.ibm.com/support/docview.wss?uid=swg27008337
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a case:
    https://www.ibm.com/mysupport/
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH53466

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-23

  • Closed date

    2023-06-01

  • Last modified date

    2023-06-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date: