IBM Support

Tivoli Log File Agent, Version 6.3.0 Fix Pack 07 Interim fix 02 (6.3.0.7-TIV-ITM_LFA-IF0002)

Download


Version

Tivoli® Log File Agent Version 6.3.0

Downloadable File

File link File size File description

Abstract

This fix pack resolves the APARs and defects that are listed in section 2.0 "Problems Fixed" and includes the superseded fixes that are listed in section 2.4.

Download Description

(C) Copyright International Business Machines Corporation 2023.
All rights reserved.
Component: Tivoli® Log File Agent, Version 6.3.0
Component: 5724C04LF
---------------------------------------------------------------------------
Interim Fix: 0002, (6.3.0.7-TIV-ITM_LFA-IF0002)
---------------------------------------------------------------------------
Date: June 20, 2023
 

1.0 General description

=======================
This fix resolves the APARs and defects that are listed in the "Problems Fixed" section below. This fix also includes the superseded fixes that are listed in section 2.3.
 

2.0 Problems fixed

=======================
The following problems are addressed by this fix.
  2.1 APARs
  -------------
     APAR: IJ45819
    Abstract: Memory leak in LFA 6.3.0 FP7
    Additional information: Log File Agent when upgraded from 6.3.0 Fix Pack 03 to 6.3.0 Fix Pack 07, high memory consumption was observed under heavy load.
    High memory leak is observed only when DISCARD event is used in the fmt file.

  2.2 Enhancements  
  ------------------
  None
  2.3 Superseded fixes
  -------------------------
    6.3.0.7-TIV-ITM_LFA-IF0001
  
  2.4 APARs and defects included from superseded fixes
  ---------------------------------------------------------------

  6.3.0.7-TIV-ITM_LFA-IF0001
  -------------------------------------
APAR: IJ39278
Abstract: LOG FILE AGENT STOPS FORWARDING EVENTS TO EIF RECEIVER WITH LARGE EVENT.
Additional information: The problem occurs when the Log File Agent is configured to send EIF events, the .conf file contains the BufferEvents and EventMaxSize keywords and an event larger than the EventMaxSize is processed. The event is written to the .cache file, but there is an issue when EIF reads the event from the .cache file to forward to the EIF receiver.
At this point no new events are being sent to the EIF receiver and the .cache file gets filled with events.
Install Actions: If the .cache file was continuing to grow due to the issue above, after the fix has been installed the agent needs to be stopped, the .cache file removed, and the agent restarted. This will result in a new .cache file being created which allow messages to be forwarded again.
DEFECT: 219237
Abstract: Log File agent crash when CTIRA_HOSTNAME not set and LABEL used.
Additional information: If the .fmt uses the keyword LABEL, for example hostname  LABEL it will try to use the value for CTIRA_HOSTNAME.  If that is not set the agent will crash.
 

3.0 Architecture and prerequisites

=======================
This fix is supported on all operating systems listed in the Tivoli Log File Agent User's Guide, version 6.3.0.
Please refer to the IBM Software Product Compatibility Reports (SPCR) for the latest operating system certification information:
http://publib.boulder.ibm.com/infocenter/prodguid/v1r0/clarity/index.html
  3.1 Prerequisites for this fix
  --------------------------------
The prerequisite level for this fix is as follows:
- IBM Tivoli Log File Agent 6.3.0 Fix Pack 07 available from Fix Central.
For details, see the Troubleshooting Wiki: https://www.ibm.com/developerworks/mydeveloperworks/wikis/home?lang=en#/wiki/Tivoli%20Monitoring/page/Log%20File%20Agent
 

4.0 Image directory contents

=======================
This fix image contains the following files:
- 6.3.0.7-TIV-ITM_LFA-IF0002.README 
- 6.3.0.7-TIV-ITM_LFA-IF0002.tar 
- 6.3.0.7-TIV-ITM_LFA-IF0002.zip
Note: The .tar and .zip files are identical in content. Use the .tar file if you are working in a UNIX® environment; use the .zip file if you are working in a Windows environment. 
The fix archive file contains the following files:
- 6.3.0.7-TIV-ITM_LFA-IF0002/kloaix523.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_aix523_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/kloaix526.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_aix526_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klohp11.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_hp11_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klohp116.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_hp116_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klohpi116.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_hpi116_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/kloli6263.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_li6263_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klols3263.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_lpl266_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klolpl266.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_ls3263_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klols3266.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_ls3266_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klolx8266.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_lx8266_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klosol283.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_sol283_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klosol286.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_sol286_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/klosol606.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_sol606_tema_IF0002.tar
- 6.3.0.7-TIV-ITM_LFA-IF0002/KLOWINNT.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_winnt_tema_IF0002.cab
- 6.3.0.7-TIV-ITM_LFA-IF0002/KLOWIX64.dsc
- 6.3.0.7-TIV-ITM_LFA-IF0002/klo_wix64_tema_IF0002.cab
- 6.3.0.7-TIV-ITM_LFA-IF0002/lo_dd_063007002.xml
- 6.3.0.7-TIV-ITM_LFA-IF0002/lo_dd.properties

5.0 Installation instructions

=======================
This fix can only be installed over an existing installation.  Use the following steps to install this fix.
  5.1 Before installing the fix 
  -------------------------------
  - The prerequisites listed under section 3.1 entitled 'Prerequisites for this fix' must be installed before this fix can be installed.
    
  - For the purpose of this README, the symbol <CANDLEHOME> is the IBM Tivoli Monitoring installation directory. The default value for CANDLEHOME is '/opt/IBM/ITM' on UNIX systems and 'C:\IBM\ITM' on Windows systems.
  - Before installing this fix on UNIX systems, set the environment variable CANDLEHOME to the IBM Tivoli Monitoring installation directory.
        
    For example: 
    > CANDLEHOME=/opt/IBM/ITM
  > export CANDLEHOME
 
  
  - As there is no uninstall utility for this fix, make sure to perform a backup of the environment before installing this fix.
  5.2 Local agent update
  --------------------------
  1. Transfer the appropriate archive file (6.3.0-TIV-ITM_LFA-IF0002.tar or .zip) to a temporary directory on the system that contains the agent to be updated. For the purpose of this README, the symbol <TEMP> represents the fully qualified path to this directory.
Note: On Windows systems, this path includes the drive letter.
  2. Expand the archive file by using the "tar" command on UNIX systems or an extract utility on Windows systems. This step creates a directory structure that contains fixes for all of the supported platforms.
     
  3. Use the "itmpatch" command to install the fix for the operating system of that agent. For more information on the "itmpatch" command, see section 6.2.  
     
On UNIX systems, if the fix was expanded to <TEMP>/6.3.0-TIV-ITM_LFA-IF0002, the install command is:
     
     > $CANDLEHOME/bin/itmpatch -h <CANDLEHOME> 
           -i <TEMP>/6.3.0-TIV-ITM_LFA-IF0002/klo_xxxxxx_tema_IF0002.tar

                
       where:
         - xxxxxx corresponds to the value in the first column returned by the ./cinfo -i command. 
       
         In the following example, the file is "klo_lx8266_tema_IF0002.tar".
         > ./cinfo -i
           lo      Tivoli Log File Agent
           lx8266  Version: 06.30.00.00
On Windows systems, if the fix was expanded to <TEMP>\6.3.0-TIV-ITM_LFA-IF0002, the install command is:
    > <TEMP>\6.3.0-TIV-ITM_LFA-IF0002\itmpatch -h <CANDLEHOME>
       -i <TEMP>\6.3.0-TIV-ITM_LFA-IF0002\klo_xxxxx_tema_IF0002.cab
where:
- xxxxx corresponds to the value in the first column returned by the ./kincinfo -i command. 

Note: The itmpatch.exe provided ITM 6.30 FP7 SP8 through SP13 has an issue on 64-bit Windows systems. For 64-bit Windows systems, you must use the itmpatch.exe provided with this interim fix.

  5.3 Remote agent update
  ----------------------------
  1. Transfer the appropriate archive file (6.3.0-TIV-ITM_LFA-IF0002.tar or .zip) to a temporary directory on the IBM Tivoli Enterprise Monitoring Server system.  For the purpose of this README, the symbol <TEMP> represents the fully qualified path to this directory.
Note: On Windows systems, this path includes the drive letter.
  2. Expand the archive file using the "tar" command on UNIX systems or an extract utility on Windows systems. This step creates a directory structure that contains fixes for all of the supported platforms.
  3. To add the agent fix bundles into the remote deploy depot, use the "tacmd addBundles" command found in $CANDLEHOME/bin on UNIX systems or in %CANDLE_HOME%\bin on Windows systems. For more information on the "tacmd addBundles" command, see the IBM Tivoli Monitoring Administrator's Guide.
     Note
     1. The prerequisite Log File Agent bundles must also be in the depot, to ensure successful completion of the remote agent update.
     On UNIX systems, 
     if the fix was expanded to <TEMP>/6.3.0-TIV-ITM_LFA-IF0002:
     > $CANDLEHOME/bin/tacmd addBundles -n 
           -i <TEMP>/6.3.0-TIV-ITM_LFA-IF0002 

     
     On Windows systems, 
     if the fix was expanded to <TEMP>\6.3.0-TIV-ITM_LFA-IF0002:
     > %CANDLE_HOME%\bin\tacmd addBundles -n 
             -i <TEMP>\6.3.0-TIV-ITM_LFA-IF0002 

     
       where:
         -n indicates that prerequisite bundles are not automatically added. The -n parameter must be used because the fix directory does not contain any prerequisites that the fix might require. See Section 3.1 for the prerequisites for this fix.
         -i is the directory that contains the deployment bundles to be added to the depot. 
  4. To log in to the Tivoli Enterprise Monitoring server, and deploy the fix to the appropriate nodes where the agent is running, use the following "tacmd" commands.  For more information on the "tacmd login" and "tacmd updateAgent" commands, see the IBM Tivoli Monitoring Administrator's Guide.
     On UNIX systems: 
     > $CANDLEHOME/bin/tacmd login -s <server>
                 -u <itmuser> 
                 -p <password>

                                   
     > $CANDLEHOME/bin/tacmd listSystems
          
     The output shows the Managed System Name for the OS agent on the remote system to be updated. Use this value as the target of the "tacmd updateAgent" command.
     
     > $CANDLEHOME/bin/tacmd updateAgent -t lo 
                -n <Managed system name>
                -v 063007002
   
 On Windows systems:
     > %CANDLE_HOME%\bin\tacmd login -s <server>
                                    -u <itmuser> 
                                    -p <password>

                                    
     > %CANDLE_HOME%\bin\tacmd listSystems
          
     The output shows the Managed System Name for the OS agent on the remote system to be updated. Use this value as the target of the "tacmd updateAgent" command.
     
     > %CANDLE_HOME%\bin\tacmd updateAgent -t LO 
                   -n <Managed system name>    
                   -v 063007002

                              
     Note:
     - The component (-t) for the "tacmd updateAgent" command is specified as two characters (LO), not three characters (KLO).
     - The node (-n) for the "tacmd updateAgent" command is the managed system name of the operating system (OS) agent to be updated.
       The target node for the "tacmd updateAgent" command is always an OS agent.
  5.4 Agent support update
  ------------------------------
  There are no agent support updates for the Tivoli Enterprise Monitoring Server, Tivoli Enterprise Portal Server, or Tivoli Enterprise Portal Desktop included in this fix. No additional installation steps are required.
  

6.0 Additional installation information

=======================
For additional troubleshooting installation information, see the itmpatch.log in the patchlogs directory in <CANDLEHOME>.
  6.1 Installation instructions for agent baroc file
  -----------------------------------------------------
  There are no updates to the baroc files included in this fix or any of the superseded fixes.  No additional installation steps are required.
 
  6.2 Additional information on using "itmpatch" command
  --------------------------------------------------------------
  The "itmpatch" command has the following syntax:
  Usage: itmpatch -h <installation home> [OPTIONS]
  itmpatch -h <installation home> 
           -t { <patch_file_directory> | <patch_file> }

           
  itmpatch -h <installation home> 
           -i { <patch_file_directory> | <patch_file> }
  where:
  -h Specifies the IBM Tivoli Monitoring installation directory
  -i  Specifies the path to the directory or patch file to be installed
  -t  Generates a report of the actions to be taken by the patch
  
  For example, on UNIX systems:
  - To preview the fix installation, use the "-t" option:
    > <CANDLEHOME>/bin/itmpatch -h <CANDLEHOME> -t <TEMP>
    
  - To install the fix, use the "-i" option:
    > <CANDLEHOME>/bin/itmpatch -h <CANDLEHOME> -i <TEMP>
    
  where:   
  <CANDLEHOME> is the fully qualified IBM Tivoli Monitoring installation directory. On Windows systems, this path must include the drive letter.
  <TEMP> represents the fully qualified directory specification, where the fix is located. On Windows systems, this must include the drive letter.
  6.3 Verifying the update
  ----------------------------
  1. To verify whether the agent was updated correctly, use the "tacmd" command to view the agent's current version after the agent is restarted.
     You are required to log in to a Tivoli Enterprise Monitoring Server prior to viewing the agent version.  
                 
     For example:
     On UNIX systems, where $CANDLEHOME is the IBM Tivoli Monitoring installation directory, the default location is '/opt/IBM/ITM'.   
    
     > $CANDLEHOME/bin/tacmd login -s <server>
                                -u <itmuser> 
                                -p <password>
     > $CANDLEHOME/bin/tacmd listSystems -t LO
     On Windows systems, where %CANDLE_HOME% is the IBM Tivoli Monitoring installation directory, the default location is 'C:\IBM\ITM'.   
     > %CANDLE_HOME%\bin\tacmd login -s <server>
                                   -u <itmuser> 
                                   -p <password>

                                     
     > %CANDLE_HOME%\bin\tacmd listSystems -t LO 
     Note: The component (-t) in the "tacmd listSystems" command is specified as two characters (LO), not three characters (KLO).
     When the agent update is successful, the agent version is 06.30.07.02.
    
    After the agent is restarted, you can also use the GUI to verify whether the agent was successfully updated.
    
    For the agent on Windows systems, the version number is 06.30.07.02.      
                                  
  2. To verify that the agent you are running contains the updates from the fix, check whether the following lines are displayed in the agent log:      
            
     <hostname>_lo_<instance>_kloagent_<timestamp>.log located in
     $CANDLEHOME/logs on UNIX systems and
     %CANDLE_HOME%\tmaitm6\logs on Windows systems:
    <timestamp>       Component: ira
    <timestamp>       Driver: agent-fac:202305170534/5337177.3
    <timestamp>       Timestamp: May 17 2023 05:43:30

7.0 Known problems and workarounds

=======================
When installing the interim fix on a Windows 64-bit system with ITM 6.30 FP7 SP8-SP13 common components installed, if you get an error while installing the fix, check the itmpatch.log file.  If the following error is displayed in the file, then re-run the itmpatch command by using the itmpatch in the directory with the patch files and not the version in %CANDLE_HOME%\bin.
ERROR 11/07/22 09:22:34 (patchprocessor.cpp,1088): Unable to extract CAB file C:\Downloads\6.3.0.7-TIV-ITM_LFA-IF0002\KLO_wix64_tema_IF0002.cab: 13
  

8.0 Additional product information

=======================
None

9.0 Copyright and trademark information

=======================
A current list of IBM trademarks is available on the Web on "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

10.0 Notices

=======================
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM
may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
Microsoft, Windows, and Windows Server are trademarks of Microsoft Corporation in the United States, other countries, or both. 
Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates. 
UNIX is a registered trademark of The Open Group in the United States and other countries.
Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
Third-Party License Terms and Conditions, Notices and Information
-----------------------------------------------------------------
The license agreement for this product refers you to this file for details concerning terms and conditions applicable to third party software code included in this product, and for certain notices and other information IBM must provide to you under its license to certain software code. The relevant terms and conditions, notices and other information are provided or referenced below. Please note that any non-English version of the licenses below is unofficial and is provided to you for your convenience only. The English version of the licenses below, provided as part of the English version of this file, is the official version.
Notwithstanding the terms and conditions of any other agreement you may have with IBM or any of its related or affiliated entities (collectively "IBM"), the third party software code identified below
are "Excluded Components" and are subject to the following terms and conditions:
- the Excluded Components are provided on an "AS IS" basis
- IBM DISCLAIMS ANY AND ALL EXPRESS AND IMPLIED WARRANTIES AND CONDITIONS WITH RESPECT TO THE EXCLUDED COMPONENTS, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF NON-INFRINGEMENT OR INTERFERENCE AND THE IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
- IBM will not be liable to you or indemnify you for any claims related to the Excluded Components
- IBM will not be liable for any direct, indirect, incidental, special, exemplary, punitive or consequential damages with respect to the Excluded Components. 

Prerequisites

The prerequisite level for this interim fix is version 6.3.0 Fix Pack 7 of Log File Agent.
      

Installation Instructions

Please refer to the full readme file contained in the Download Description section above for general installation instructions.

On
[{"DNLabel":"6.3.0.7-TIV-ITM_LFA-IF0002","DNDate":"09 Jun 2023","DNLang":"English","DNSize":"76840647 B","DNPlat":{"label":"AIX","code":"PF002"},"DNURL":"http://www.ibm.com/support/fixcentral/quickorder?fixids=6.3.0.7-TIV-ITM_LFA-IF0002&product=ibm/Tivoli/IBM Tivoli Monitoring&source=dbluesearch&platform=All","DNURL_FTP":"","DDURL":null}]

Document Location

Worldwide

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"ARM Category":[{"code":"a8m0z0000001f3sAAA","label":"LogFile Agent"}],"Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"6.3.0"}]

Product Synonym

5724C04LF; Tivoli Log File Agent; Version 6.3.0 Fix Pack 07 Interim fix 02

Document Information

Modified date:
27 November 2023

UID

ibm17001605