IBM Support

OA64822: ABEND=S01C5,REASON=000A0013 AT IXGF1WOW + X'CF36' WHEN PCNTL_AOCTL_INUSE IS SET TO OFF WHEN WE EXPECT IT TO BE ON.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND1C5 REASON=000A0013 is encountered during offload
    processing after turning on LS_ALLOCAHEAD in a logstream with
    active connectors. The abend is due to a mismatch setting of two
    bits.
    
    During the transition of the LS_ALLOCAHEAD logstream attribute
    from pending to no longer pending there are two paths that can
    cause bits PCNTL_AOctl_inuse and Lcb_AdvCurds_ProActive to not
    be in sync, leaving Lcb_AdvCurds_ProActive On and
    PCNTL_AOctl_inuse off:
    
    1. If the logger structure becomes full during dataset switch
    processing.
    2. If logger structure duplexing is stopped and restarted
    without a rebuild in between
    
    VERIFICATION STEPS:
    Confirm PCNTL_AOctl_inuse is off while Lcb_AdvCurds_ProActive is
    on and one of the conditions described in the Error
    Description has occurred.
    
    For data set switch processing look for CTRACE entry AOCTL
    CREATE FAILED.
    

Local fix

  • RECOVERY ACTION:
    Disconnect and reconnect the logstream.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of HBB77D0 and above releases                          *
    * using System Logger Services and the                         *
    * LS_ALLOCAHEAD log stream attribute.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ABEND1C5 RSN000A0013 occurs during                           *
    * offload processing while the                                 *
    * activation of the LS_ALLOCAHEAD                              *
    * log stream attribute is pending                              *
    * and one of two of the following                              *
    * events has occurred:                                         *
    * 1) During data set switch processing,                        *
    *    a call to IXLLIST WRITE fails due                         *
    *    to the structure being full                               *
    * 2) Structure duplexing rebuild was                           *
    *    previously performed                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    ABEND1C5 RSN000A0013 indicates an inconsistency with
    the LS_ALLOCAHEAD attribute between 2 internal control
    blocks.  This APAR addresses two specific situations
    that will result in the ABEND appearing:
    
    1) ABEND issued during offload processing while
       the activation of the LS_ALLOCAHEAD log stream
       attribute is pending and during data set switch
       processing, a call to IXLLIST WRITE fails with
       RC0C, RSN0C1C0C17 (structure is full).
    
    2) ABEND issued during offload processing while
       the activation of the LS_ALLOCAHEAD log stream
       attribute is pending and a structure duplexing
       rebuild was previously performed.
       (example: SETXCF START,REBUILD,DUPLEX,STRNAME=xxx)
    

Problem conclusion

  • System Logger is changed to ensure the 2 internal
    control blocks representing the LS_ALLOCAHEAD
    attribute are in a consistent state after:
    
    1) The data set switch processing recovers from
       the IXLLIST WRITE failure.
    
    2) The structure duplexing rebuild is performed.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    OA64822

  • Reported component name

    SYSTEM LOGGER

  • Reported component ID

    5752SCLOG

  • Reported release

    7D0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-08

  • Closed date

    2023-08-10

  • Last modified date

    2023-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ93485 UJ93486

Modules/Macros

  • IXGC4RBE IXGI3DSE IXGV1FMT
    

Fix information

  • Fixed component name

    SYSTEM LOGGER

  • Fixed component ID

    5752SCLOG

Applicable component levels

  • R7D0 PSY UJ93486

       UP23/08/23 P F308 ¢

  • R7E0 PSY UJ93485

       UP23/08/23 P F308 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7D0"}]

Document Information

Modified date:
05 September 2023