A fix is available
APAR status
Closed as program error.
Error description
ABEND1C5 REASON=000A0013 is encountered during offload processing after turning on LS_ALLOCAHEAD in a logstream with active connectors. The abend is due to a mismatch setting of two bits. During the transition of the LS_ALLOCAHEAD logstream attribute from pending to no longer pending there are two paths that can cause bits PCNTL_AOctl_inuse and Lcb_AdvCurds_ProActive to not be in sync, leaving Lcb_AdvCurds_ProActive On and PCNTL_AOctl_inuse off: 1. If the logger structure becomes full during dataset switch processing. 2. If logger structure duplexing is stopped and restarted without a rebuild in between VERIFICATION STEPS: Confirm PCNTL_AOctl_inuse is off while Lcb_AdvCurds_ProActive is on and one of the conditions described in the Error Description has occurred. For data set switch processing look for CTRACE entry AOCTL CREATE FAILED.
Local fix
RECOVERY ACTION: Disconnect and reconnect the logstream.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of HBB77D0 and above releases * * using System Logger Services and the * * LS_ALLOCAHEAD log stream attribute. * **************************************************************** * PROBLEM DESCRIPTION: * * ABEND1C5 RSN000A0013 occurs during * * offload processing while the * * activation of the LS_ALLOCAHEAD * * log stream attribute is pending * * and one of two of the following * * events has occurred: * * 1) During data set switch processing, * * a call to IXLLIST WRITE fails due * * to the structure being full * * 2) Structure duplexing rebuild was * * previously performed * **************************************************************** * RECOMMENDATION: * **************************************************************** ABEND1C5 RSN000A0013 indicates an inconsistency with the LS_ALLOCAHEAD attribute between 2 internal control blocks. This APAR addresses two specific situations that will result in the ABEND appearing: 1) ABEND issued during offload processing while the activation of the LS_ALLOCAHEAD log stream attribute is pending and during data set switch processing, a call to IXLLIST WRITE fails with RC0C, RSN0C1C0C17 (structure is full). 2) ABEND issued during offload processing while the activation of the LS_ALLOCAHEAD log stream attribute is pending and a structure duplexing rebuild was previously performed. (example: SETXCF START,REBUILD,DUPLEX,STRNAME=xxx)
Problem conclusion
System Logger is changed to ensure the 2 internal control blocks representing the LS_ALLOCAHEAD attribute are in a consistent state after: 1) The data set switch processing recovers from the IXLLIST WRITE failure. 2) The structure duplexing rebuild is performed.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
OA64822
Reported component name
SYSTEM LOGGER
Reported component ID
5752SCLOG
Reported release
7D0
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-05-08
Closed date
2023-08-10
Last modified date
2023-09-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ93485 UJ93486
Modules/Macros
IXGC4RBE IXGI3DSE IXGV1FMT
Fix information
Fixed component name
SYSTEM LOGGER
Fixed component ID
5752SCLOG
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.