APAR status
Closed as program error.
Error description
427-DR Prescriber Name is only required if 411-DB PRESCRIBER ID is not known or to validate 411-DB. NCPDP Transactions are failing compliance when 427-DR is not present but 411-DB is present. There is not a way for the compliance check to know 411-DB is needed for validation so the transaction should not fail when for 427-DR not being present when 411-DB is present. Failure only occurs if the transaction is out of balance, eventhough balancing edit has been turned off.
Local fix
ITXCQ - ITX00061680 LV / LV Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare NCPDP Problem Description: Transaction are failing compliance when 427-DR is not present but 411-DB is present. Platforms Affected: ALL
Problem conclusion
There was a rule to enforce that if 411-DB is absent, then 427-DR is required. This had an error in the definition, so was not actually checking 411-DB. This has been corrected. Applies to: Healthcare Pack 10.1, 10.2 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/t ransformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH51053
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-21
Closed date
2022-12-19
Last modified date
2023-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
27 April 2023