APAR status
Closed as program error.
Error description
The affected pod(s) would show that one or more container restarts have occurred and the pod is Running but not Ready. ``` NAME READY STATUS RESTARTS gwv6-0 1/1 Running 0 gwv6-1 0/1 Running 1 gwv6-2 1/1 Running 0 ``` The gwd-log.log file of the affected pod(s) would show repeated entries similar to the following: ``` lib:gateway-controller:apigateway:ApiGatewayConfigStatus: Refreshing /opt/ibm/datapower/drouter/temporary/apiconnect/file stores/extensions/gateway-extension/0.remove lib:gateway-controller:apigateway:ApiGatewayConfigStatus: Getting stat for /opt/ibm/datapower/drouter/temporary/apiconnec t/filestores/extensions/gateway-extension/0.remove.cfg lib:gateway-controller:apigateway:ApiGatewayConfigStatus: Getting stat for /opt/ibm/datapower/drouter/temporary/apiconnec t/filestores/extensions/gateway-extension/0.remove.log lib:gateway-controller:apigateway:ApiGatewayConfigStatus: Failed to get stat for /opt/ibm/datapower/drouter/temporary/apiconnect /filestores/extensions/gateway-extension/0.remove.log:Error: ENO lib:gateway-controller:apigateway:ApiGatewayConfigStatus: /opt/ ibm/datapower/drouter/temporary/apiconnect/filestores/extension s/gateway-extension/0.removeis NOT up-to-date: No log stat ```
Local fix
Problem summary
A gateway pod might not getting to ready status after container reload.
Problem conclusion
Fix is available in 10.0.1.13 and 10.5.0.5. For a list of the latest fix packs available, please see: https://www.ibm.com/support/pages/node/83105
Temporary fix
Comments
APAR Information
APAR number
IT42681
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
A0X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-12-09
Closed date
2023-04-18
Last modified date
2023-04-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A0X","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
26 April 2023