Error description
HIPAA Compliance - passthrough map is not reporting SNIP 1-4 errors for 277CA. Below are the errors that were not reported in the HIPAA passthrough map. They are identified in the 277CA: 1) Secondary ID sent in REF segment when NPI was sent in NM109 2) Invalid value in QTY02
Local fix
ITXCQ - ITX00061472 EY / EY Circumvention: None
Problem summary
Users Affected: IBM Transformation Extender Pack for Healthcare HIPAA Problem Description: QTY03 should not be 0 for 277CA (type 2), Loop 2200C Provider Secondary Identifier REF should not present if NPI in 2100C NM109 (type 4). Platforms Affected: ALL
Problem conclusion
Component rules added to the hipaa type trees so data with QTY03 = 0 or REF present if NPI also present will fail type tree validation. Applies to: Healthcare Pack HIPAA 9.0.2, 10.0.0, 10.0.3, 10.1.0, 10.2.0 Fixed in the next service packs and releases. To obtain the fix for this APAR: To see if the next service pack or product release is available, check the IBM Transformation Extender Downloads page: http://www.ibm.com/support/entry/portal/product/other_software/t ransformation_extender If the service pack or product release is available, download it from Fix Central: http://www.ibm.com/support/fixcentral/ If the service pack or product release is not available and you require the APAR fix immediately, request a Limited Availability Interim Fix (LAIF) by opening a PMR: http://www.ibm.com/support/servicerequest/Home.action Prior to version 9.0.0, IBM Transformation Extender was called IBM WebSphere Transformation Extender.
Temporary fix
Comments
APAR Information
APAR number
PH50951
Reported component name
ITX
Reported component ID
5724Q2300
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-16
Closed date
2023-03-10
Last modified date
2023-04-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITX
Fixed component ID
5724Q2300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]
Document Information
Modified date:
11 April 2023