IBM Support

fn_setup_rdb -u Fails with 'sqlcmd.exe' and 'osql.exe' Not Recognized Errors After MSSQL 2019 Client Upgrade in FileNet IS

Troubleshooting


Problem

  • When fn_setup_rdb -u is executed, fn_msodbc returned an error that osql could not be executed.
  • sqlcmd.exe not always executed when osql.exe is missing.

Symptom

The following errors are reported in the elog
fn_msodbc: ERROR MSSQL Server Software was not installed on this home directory.

ERROR: The following error may mean SQL Server is not installed or
The SQL Server Tools\binn directory is missing from the environment PATH:
'sqlcmd.exe' is not recognized as an internal or external command,
Operable program or batch file.
'osql' is not recognized as an internal or external command,
Operable program or batch file.
Please verify system configuration is correct.
2023/02/14 04:56:36.759 212,6,31 HGNYZ0031E <Administrator> fn_get_input.exe  FN_GET_MSSQL_2005_UPGRADE (2108.4184.0 0x83c.1058) ... [SERIOUS]
ERROR: The following error may mean SQL Server is not installed or
The SQL Server Tools\binn directory is missing from the environment PATH:
'sqlcmd.exe' is not recognized as an internal or external command,
Operable program or batch file.
Please verify system configuration is correct.
Error occurred while Granting VIEW SERVER STATE to IS users or while setting ANSI_NULL_DFLT_ON to ON
fn_setup_rdb terminated abnormally.
Running fn_util upgrade_to_odbc 2019
        fn_util, odbc: starting 'upgrade_to_odbc'
fn_msodbc: ERROR MSSQL Server Software was not installed on this home directory.

Document Location

Worldwide

[{"Type":"MASTER","Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSNVUD","label":"FileNet Image Services"},"ARM Category":[{"code":"a8m50000000Ce0AAAS","label":"FileNet Image Manager Active Edition (Click on +)-\u003EFileNet Image Services-\u003EData Bases-\u003EMicrosoft SQL DB"}],"ARM Case Number":"","Platform":[{"code":"PF033","label":"Windows"}],"Version":"4.1.2;4.2.0"}]