A fix is available
APAR status
Closed as program error.
Error description
When executing expansion for Safeguarded Copy volumes to a capacity of or exceeding 1,000,000 cylinders, the following error may be encountered: C 798 +++ bv_mult = right((bv_sev_cap % sev_cap),5,0) C 285 +++ sgc_ret = dvcTask() C IRX0041I Error running VPCESGC1, line 798: Bad arithmetic conversion
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: GDPS LCP users * * * * keywords: GDPSLCPMGR/K * **************************************************************** * PROBLEM DESCRIPTION: Safeguarded Copy volume expansion * * causes REXX arithmetic error * **************************************************************** Executing expansion for Safeguarded Copy volumes to a capacity of or exceeding 1,000,000 cylinders may result in a REXX arithmetic error.
Problem conclusion
This PTF corrects the reported problem
Temporary fix
Comments
APAR Information
APAR number
PH51851
Reported component name
GDPS
Reported component ID
694235B00
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-11
Closed date
2023-03-30
Last modified date
2023-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI91211 UI91212 UI91213
Modules/Macros
VPCELCS3 VPCESGC1 VPCESGC2
Fix information
Fixed component name
GDPS
Fixed component ID
694235B00
Applicable component levels
R430 PSY UI91213
UP23/03/31 P F303
R440 PSY UI91212
UP23/03/31 P F303
R450 PSY UI91211
UP23/03/31 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"430"}]
Document Information
Modified date: