APAR status
Closed as program error.
Error description
PBV003E:invalid value specified while making changes in the initparm.cfg file with the CCD . SCCD version = IBM Sterling Control Center Director - Version 6.02.01.00_iFix09 CD Version = 6.1.0.4_iFix062UNIX
Local fix
STRRTC - MFT-14112 CN / SF Circumvention: None
Problem summary
Description of issue: Valid initialization parameters and values are erroneously flagged as invalid, and Connect:Direct UNIX initialization parameter values are not allowed to be continued across multiple lines.
Problem conclusion
Description of fix: The initialization parameter parsing and validation logic was updated, and the initparmValidation.properties data was changed as follows: ? Updated ZOS.IMMEDIATE.SHUTDOWN = SELECTION [I|R]|[I,0-999]|[R,0-999] ? Updated ZOS.STAT.TPREC = SELECTION [,,1-60]|['TIME 8',,1-60]|[,'TIME 8',1-60]|['TIME 8','TIME 8',1-60] ? Added ZOS.TCP.FMH.TIMER.RETRIES = RANGE 1-100 ? Replaced ZOS.ZIIP.EXTCOMP.DATASIZE with ZOS.ZIIP.EXTCOMP.DATASIZE.THRESHOLD = RANGE 512-65536 ? Updated UNIX.options = SELECTION []|['STRING',...20] (Note Also requires parser update to validate) ? Added UNIX.recv.file.open.perm = RANGE 0 - 999 ? Added UNIX.recv.file.open.ovrd = SELECTION y|Y|n|N|p|P ? Added UNIX.fsync.after.receive = SELECTION y|Y|n|N ? Updated UNIX.license.edition = SELECTION [PREMIUM|premium|Premium|STANDARD|standard|Standard|SOLO|solo|So lo] ? Updated UNIX.license.type = SELECTION PRODUCTION|production|Production|NON-PRODUCTION|non-production|N on-Production|Non-production ? Added UNIX.license.vpc = RANGE 0-2147483647 ? Added UNIX.agent.installation_id = SELECTION []|['STRING'] ? Updated UNIX.osa.rest.url = SELECTION []|['URLSEMI'] (Note Also requires parser update to validate) ? Updated UNIX.osa.disable = SELECTION []|y|n|Y|N ? Added UNIX.installer.location = STRING 1024 ? Added UNIX.cd.backup = STRING 1024 ? Added UNIX.agent.backup = STRING 1024 ? Added UNIX.emergency_restore.installers = STRING 1024 ? Added UNIX.process.dir = STRING 1024 ? Added UNIX.trusted.addr = SELECTION []|['STRING',...8] ? Added WIN.password.exit.dll = SELECTION <NONE>|'STRING' ? Added WIN.password.exit.hash = SELECTION <NONE>|'STRING' ? Added WIN.password.exit.appl.id = SELECTION <NONE>|'STRING' ? Added WIN.password.exit.policy.id = SELECTION <NONE>|'STRING' ? Added WIN.password.exit.url = SELECTION <NONE>|'STRING' ? Added WIN.instance.id = STRING 255 ? Added WIN.trusted.addr = SELECTION <NONE>|'STRING',...8 ? Updated WIN.license.edition = SELECTION PREMIUM|premium|Premium|STANDARD|standard|Standard|SOLO|solo|Sol o|<None> ? Updated WIN.license.type = SELECTION PRODUCTION|production|Production|NON-PRODUCTION|non-production|N on-Production|Non-production|<None> ? Updated WIN.agent.installation_id = SELECTION <NONE>|'STRING'
Temporary fix
Comments
APAR Information
APAR number
IT43289
Reported component name
STR CONTROL CEN
Reported component ID
5725D0200
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-06
Closed date
2023-03-15
Last modified date
2023-03-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CONTROL CEN
Fixed component ID
5725D0200
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
16 March 2023