APAR status
Closed as program error.
Error description
When opening a file with DIO and issuing AIO I/O requests, the requests need to be aligned to the sector size. This is enforced by GPFS and an error is returned. The problem here was that an internal error code was returned (795), instead an error code that is recognized by Linux applications
Local fix
Problem summary
When opening a file with DIO and issuing AIO I/O requests, the requests need to be aligned to the sector size. This is enforced by GPFS and an error is returned. The problem here was that an internal error code was returned (795), instead an error code that is recognized by Linux applications
Problem conclusion
This problem is fixed in 5.1.2.10 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: A valid Linux error code is returned for this case, that applications can handle. Work Around: None Problem trigger: Open a file for DIO and issue I/O requests through AIO. Symptom: Unexpected Results/Behavior Platforms affected: ALL Linux OS environments Functional Area affected: All Scale Users Customer Impact: Suggested
Temporary fix
Comments
APAR Information
APAR number
IJ45540
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
512
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-22
Closed date
2023-03-03
Last modified date
2023-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Line of Business":{"code":"LOB26","label":"Storage"}}]