A fix is available
APAR status
Closed as program error.
Error description
Abend S0C7 in DP batch module EQQDPOOP when trying to convert the actual end date/time of an operation. . Dump Symptoms: SYSTEM COMPLETION CODE=0C7 REASON CODE=00000000 TIME=09.05.11 SEQ=16345 CPU=0000 ASID=01E8 PSW AT TIME OF ERROR 078D0000 801CB8AC ILC 4 INTC 07 ACTIVE MODULE ADDRESS=00000000_00117E90 OFFSET=000B3A1C NAME=EQQDNTOP DATA AT PSW 001CB8A6 - D0684F20 D070A768 00031882 AR/GR 0: 00000000/00000078 1: 00000000/00031D40 2: 01010039/0002F000 3: 00000000/1E4EA22A 4: 00000000/1E4E9FE0 5: 00000000/0002F000 6: 00000000/1E4EA22D 7: 00000000/0017F068 8: 00000000/0017D068 9: 00000000/0017E068 A: 00000000/1E4EA22D B: 00000000/001CB728 C: 00000000/00031974 D: 00000000/00031D40 E: 01010039/8017E108 F: 00000000/0002F000
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All WAz users * * * * FUNCTION=DP batch and WSA task * **************************************************************** * PROBLEM DESCRIPTION: An abend S0C7 of DP batch may occur * * when trying to work with actual end * * date. * **************************************************************** An abend S0C7 of DP batch may occur when trying to work with actual end date of an operation.
Problem conclusion
The abend was caused by binary zeros filling in the actual end time field of an operation ended in error with error code LOOP set by Workstation Analyzer. The fix was done both in the DP batch to prevent the abend and in the WSA to avoid setting zeros in that situation.
Temporary fix
Comments
APAR Information
APAR number
PH48268
Reported component name
TIV WRKLD SCHD
Reported component ID
5697WSZ01
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-27
Closed date
2023-03-08
Last modified date
2024-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI90872 UI90873 UI90874
Modules/Macros
EQQDPOOP EQQWAJOB
Fix information
Fixed component name
TIV WRKLD SCHD
Fixed component ID
5697WSZ01
Applicable component levels
R932 PSY UI90872
UP23/03/09 P F303
R952 PSY UI90874
UP23/03/09 P F303
RA12 PSY UI90873
UP23/03/09 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.