APAR status
Closed as program error.
Error description
In AIX v7.3, restvg will unexpectedly change the log file system setting to "log=INLINE"
Local fix
Problem summary
In AIX v7.3, restvg will unexpectedly change the log file system setting to "log=INLINE". The log was initially created as OUTLINE
Problem conclusion
Check the savevg data for type of log file and restore accordingly