A fix is available
APAR status
Closed as program error.
Error description
An ABENDS378 RC0C can occur near IQCCIN10 + x'0BDA' or IQCCIN20 + x'06F2' when restarting IMS and when the DIAGxx IGVUNCOND trap is set. REASON CODE=0000000C Additional Symptom: The timing at which the problem occurs can cause a different reason code as follows: An ABENDS378 RC18 or RC14 can occur near CSLSDR20 + x'0574' when shutting down IMS and when the DIAGxx IGVUNCOND trap is set. REASON CODE=00000018 REASON CODE=00000014
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Queue Control Facility for z/OS * * Version 3 Release 2 (FMID=H0GN320) users. * **************************************************************** * PROBLEM DESCRIPTION: An ABENDS378 RC0C can occur near * * IQCCIN10+x'0BDA' or IQCCIN20+x'06F2' * * when restarting IMS and when the DIAGxx * * IGVUNCOND trap is set. * * REASON CODE=0000000C * * * * The timing at which the problem occurs * * can cause a different reason code as * * follows: * * An ABENDS378 RC18 or RC14 can occur * * near CSLSDR20+x'0574' when shutting * * down IMS and when the DIAGxx IGVUNCOND * * trap is set. * * REASON CODE=00000018 * * REASON CODE=00000014 * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** QCF extensions running in the IMS CTL region tries to release storage for some work areas using the wrong PSW key during initial and termination processing. It usually does not notice this defect because it issues the STORAGE RELEASE macro with the COND=YES option. An ABENDS378 occurs when the DIAGxx IGVUNCOND trap is set.
Problem conclusion
QCF has been changed to release storage using the correct PSW key.
Temporary fix
Comments
APAR Information
APAR number
PH52060
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-20
Closed date
2023-03-28
Last modified date
2023-04-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI91152
Modules/Macros
IQCCIN0E IQCCIN0F IQCCIN1E IQCCIN1F IQCCIN2E IQCCIN2F
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI91152
UP23/03/30 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.