IBM Support

IT38501: BIPMQTT PROCESS FAIL TO START DUE TO BIP2063W WARNING

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • bipMQTT process fail to start due to below warning
    
    BIP2063W: Process bipMQTT has failed to start in 252 successive
    attempts. The next restart attempt will occur in 300 seconds.
    
    This happens only in specific machines like Redhat Linux
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of App Connect Enterprise V11.0 and V12.0
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The product by default creates a configuration file with
    bind_address set to 'localhost'. On certain operating systems
    bipMQTT process may fail to start  with following warning
    
    BIP2063W: Process bipMQTT has failed to start..
    
    The bipMQTT would start OK if an IP address is specified.
    

Problem conclusion

  • Product provides an environment variable
    MQSI_MQTT_LOCAL_HOSTNAME which can be set to 127.0.0.1 to
    resolve the error.
    User needs to perform following activity :
    - Stop the Integration Node
    - Delete the configuration file that has the same name as
    Integration Node   from  $MQSI_WORKPATH/Components/<Int
    Node>/config/
    - export MQSI_MQTT_LOCAL_HOSTNAME=127.0.0.1
    - Start the Integration Node
    
    This should recreate the configuration file with  bind_address
    set to 127.0.0.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT38501

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-27

  • Closed date

    2023-02-03

  • Last modified date

    2023-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 February 2023