The use of WAN optimization devices such as Riverbed is not supported in native Ethernet IP partnership configurations containing Storwize V7000.


Clustered Systems

A Storwize V7000 system at version 7.5 and higher requires native Fibre Channel SAN or alternatively 8Gbps/16Gbps Direct Attach Fibre Channel connectivity for communication between all nodes in the local cluster. Fibre Channel over Ethernet ( FCoE ) connectivity for communication between all nodes in the local cluster is also supported.

Partnerships between systems for Metro Mirror or Global Mirror replication can be used with both Fibre Channel, Native Ethernet connectivity and FCoE connectivity, however direct FCoE links are only supported to a maximum of 300 metres. Distances greater than 300 metres are only supported when using an FCIP link or Fibre Channel between source and target.

Direct Attachment

For information on support configurations using direct attachment please visit the following document

Direct Attachment of Storwize and SAN Volume Controller Systems

Encryption
Minimum required Storwize V7000 software level for encryption is V7.4.0.2.

If using encryption in a cluster containing both Gen1 and Gen2 Storwize V7000 control enclosures, all Gen2 control enclosures (2076-524) must have encryption licensed and enabled. With this configuration, only RAID arrays/MDisks on the Gen2 control enclosure(s) can enable encryption.


Cisco Nexus
The minimum level of Cisco Nexus firmware supported for FCoE with the IBM Storwize V7000 Gen2 is 5.2(1)N1(2a).


16Gbps Fibre Channel Canister Connection

Please see SSIC for supported 16Gbps Fibre Channel configurations supported with 16Gbps node hardware. Note 16Gbps Node hardware is supported when connected to Brocade and Cisco 8Gbps or 16Gbps fabrics only. Direct connections to 2Gbps or 4Gbps SAN or direct host attachment to 2Gbps or 4Gbps ports is not supported. Other configured switches which are not directly connected to the16Gbps Node hardware can be any supported fabric switch as currently listed in SSIC.


IP Partnership

Using an Ethernet Switch to convert a 10Gbps IP partnership link to 1Gbps link and vice versa is not supported. Therefore, the IP infrastructure on the two partnership sites should both be 1Gbps or 10Gbps. However, bandwidth limiting on 10Gbps and 1Gbps IP partnership between sites is supported.

Fabric Limitations

Only one FCF ( Fibre Channel Forwarder ) switch per fabric is supported.


HyperSwap

When using the HyperSwap function with software version 7.5 and higher, please configure your host multipath driver to use an ALUA-based path policy.

Due to the requirement for multiple access IO groups, iSCSI and SAS attached host types are not supported with HyperSwap volumes.

AIX Live Partition Mobility (LPM)


AIX LPM is not currently supported with the HyperSwap function.



VMware vSphere Virtual Volumes (VVols)

The use of VMware vSphere Virtual Volumes (VVols) on a system that is configured for HyperSwap is not currently supported with SVC/Storwize.


DS4000 Maintenance

Storwize V7000 supports concurrent ESM firmware upgrades for those DS4000 models listed as such on the Supported Hardware List when they are running either 06.23.05.00 or later controller firmware. However, controllers running firmware levels earlier than 06.23.05.00 will not be supported for concurrent ESM upgrades. Customers in this situation, who wish to gain support for concurrent ESM upgrades, will need to first upgrade the DS4000 controller firmware level to 06.23.05.00. This action is a controller firmware upgrade, not an ESM upgrade and concurrent controller firmware upgrades are already supported in conjunction with Storwize V7000. Once the controller firmware is at 06.23.05.00 or later the ESM firmware can be upgraded concurrently.

Note: The DS4000 ESM firmware upgrade must be done on one disk expansion enclosure at a time. A 10 minute delay from when one enclosure is upgraded to the start of the upgrade of another enclosure is required. Confirm via the Storage Manager applications "Recovery Guru" that the DS4000 status is in an optimal state before upgrading the next enclosure. If it is not, then do not continue ESM firmware upgrades until the problem is resolved.


Host Limitations

Microsoft Offload Data Transfer ( ODX ) and SDDDSM Requirements

Storwize V7000 version 7.5.0 introduced support for Microsft ODX. In order to utilise this function all windows hosts accessing Storwize V7000 are required to be at a minimum SDDDSM version of 2.4.5.0. Earlier versions of SDDDSM are not supported when the ODX function is activated.

Windows NTP server

The Linux NTP client used by Storwize V7000 may not always function correctly with Windows W32Time NTP Server


TPC Restrictions

TPC Supported Versions
The minimum supported TPC version for SVC/Storwize version 7.5 is TPC 5.2.6.

Vdisk Migration
When a vdisk is migrated between a child pool and its parent, or between child pools of the same parent, it is necessary to re-probe the cluster from TPC as no event is logged on the cluster for this type of migration

Migrations between non-child pools also currently require a re-probe

These issues will be addressed in future releases of TPC and SVC/Storwize Code.


Oracle

Oracle Version and OS
Restrictions that apply:
Oracle Release 11.2 any platform
1
Oracle Release 12.1 any platform
Restriction 1:
Oracle ASM disk groups may dismount with the following error

"Waited 15 secs for write IO to PST"

Recommendation

Increase the asm_hbeatiowait to 120 seconds to prevent this issue occurring.

Applies to Oracle Database - Enterprise Edition - Version 11.2.0.3 to 12.1.0.1 [Release 11.2 to 12.1] on any platform




Priority Flow Control for iSCSI

Priority Flow Control for iSCSI is supported on Brocade VDX 10-gigabit Ethernet switches only.



Maximum Configurations

Configuration limits for Storwize V7000:

Maximum WWPNs per host Object and iSCSI Names

The maximum number of FC/SAS/FCoE hosts ports supported per host object is now 32 (previously 512).
The maximum number of iSCSI names supported per host object is now 8 (previously 256).

Please see the following document

http://www-01.ibm.com/support/docview.wss?uid=ssg1S1005261


Property
Maximum Number
Comments
System (Cluster) Properties
Control enclosures per system (cluster)
4
Each control enclosure contains two node canisters
Nodes per system
8
Arranged as four I/O groups
Nodes per fabric
64
Maximum number of maximum number of SVC or Storwize family system nodes that can be present on the same Fibre Channel fabric, with visibility of each other
Fabrics per V7000 system
6
The number of counterpart Fibre Channel SANs which are supported
- Up to 4 fabrics using native Fibre Channel ports
- Up to 2 fabrics using FCoE ports
Fabrics per V7000 Gen 2 system
8
The number of counterpart SANs which are supported
Inter-cluster partnerships per system
3
A system may be partnered with up to three remote systems. No more than four systems may be in the same connected set
USB ports
2

Node Properties
Logins per node Fibre Channel port
512
Includes logins from server HBAs, disk controller ports, node ports within the same system and node ports from remote systems
Fibre Channel buffer credits per port - 8Gbps FC Adapter
255
The number of credits granted by the switch to the node
Fibre Channel buffer credits per port - 16Gbps FC Adapter
4095
The number of credits granted by the switch to the node
iSCSI sessions per node
256
512 in IP failover mode (when partner node is unavailable)
Managed Disk Properties
Managed disks (MDisks) per system
4096
The maximum number of logical units which can be managed by a system, including internal arrays.

This number also includes external MDisks which have not been configured into storage pools (managed disk groups)
Managed disks per storage pool (managed disk group)
128

Storage pools per system
1024

Parent pools per system
128

Child pools per system
1023

Managed disk extent size
8192 MB

Capacity for an individual internal managed disk (array)
1 PB
No limit is imposed beyond the maximum number of drives per array limits.
Maximum size is dependent on the extent size of the Storage Pool.
Comparison Table: Maximum Volume, MDisk and System capacity for each extent size.
Capacity for an individual external managed disk
1 PB
Note: External managed disks larger than 2 TB are only supported for certain types of storage systems. Refer to the supported hardware matrix for further details.
Maximum size is dependent on the extent size of the Storage Pool.
Comparison Table: Maximum Volume, MDisk and System capacity for each extent size.
Total storage capacity manageable per system
32 PB
Maximum requires an extent size of 8192 MB to be used

This limit represents the per system maximum of 2^22 extents.

Comparison Table: Maximum Volume, MDisk and System capacity for each extent size.
Volume (Virtual Disk) Properties
Volumes (VDisks) per system
8192
Maximum requires a system containing four control enclosures; refer to the volumes per I/O group limit below
Volumes per I/O group
(volumes per caching I/O group)
2048

Volumes accessible per I/O group
8192

Thin-provisioned (space-efficient) volume copies per system
8192
No limit is imposed here beyond the volume copies per system limit.
Compressed volume copies per V7000 Gen1 system
800
Maximum requires a system containing four control enclosures; refer to the compressed volume copies per I/O group limit below
Compressed volume copies per V7000 Gen1 I/O group
200

Compressed volume copies per V7000 Gen2 system
2048
Maximum requires a system containing four control enclosures; refer to the compressed volume copies per I/O group limit below
Compressed volume copies per V7000 Gen2 I/O group
512
With 32GB Cache upgrade and 2nd Compression Accelerator card installed.
Volumes per storage pool
-
No limit is imposed beyond the volumes per system limit
Fully-allocated volume capacity
256 TB
Maximum size for an individual fully-allocated volume.

Maximum size is dependent on the extent size of the Storage Pool.
Comparison Table: Maximum Volume, MDisk and System capacity for each extent size.
Thin-provisioned (space-efficient) volume capacity
256 TB
Maximum size for an individual thin-provisioned volume.

Maximum size is dependent on the extent size of the Storage Pool.
Comparison Table: Maximum Volume, MDisk and System capacity for each extent size.
Compressed volume capacity
96 TB
Maximum size for an individual compressed volume

Maximum size is dependent on the extent size of the Storage Pool.
Comparison Table: Maximum Volume, MDisk and System capacity for each extent size.
Host mappings per system
20,000
See also - volume mappings per host object below
Mirrored Volume (Virtual Disk) Properties
Copies per volume
2

Volume copies per system
8192

Total mirrored volume capacity per I/O group
1024 TB

Generic Host Properties
Host objects (IDs) per system
2048
A host object may contain both Fibre Channel ports and iSCSI names
Host objects (IDs) per I/O group
512
Refer to the additional Fibre Channel and iSCSI host limits below
Volume mappings per host object
2048*
* This limit is 512 for Solaris OS
Total Fibre Channel ports and iSCSI names per system
8192

Total Fibre Channel ports and iSCSI names per I/O group
2048

Total Fibre Channel ports and iSCSI names per host object
32

iSCSI names per host object (ID)
8

Fibre Channel Host Properties (including hosts attached using FCoE)
Fibre Channel hosts per system
2048

Fibre Channel host ports per system
8192

Fibre Channel hosts per I/O group
512

Fibre Channel host ports per I/O group
2048

Fibre Channel hosts ports per host object (ID)
32

Port logins (4x 8Gb FC)
1024

Port logins (2x 16Gb FC)
2048

Simultaneous I/Os (4x 8Gb FC)
2048

Simultaneous I/Os (2x 16Gb FC)
4096

iSCSI Host Properties
iSCSI hosts per system
1024

iSCSI hosts per I/O group
256

iSCSI names per host object (ID)
8

iSCSI names per I/O group
256

Copy Services Properties
Remote Copy (Metro Mirror and Global
Mirror) relationships per
system
8192
This can be any mix of Metro Mirror and Global Mirror relationships.
Active-Active Relationships
1024

Remote Copy relationships per consistency group
-
No limit is imposed beyond the Remote Copy relationships per system limit
Remote Copy consistency
groups per system
256

Total Metro Mirror and Global Mirror volume capacity per I/O group
1024 TB
This limit is the total capacity for all master and auxiliary volumes in the I/O group.
Total number of Global Mirror with Change Volumes relationships per system
256
Change volumes used for active-active relationships do not count towards this limit.
FlashCopy mappings per system
4096

FlashCopy targets
per source
256

FlashCopy mappings
per consistency group
512

FlashCopy consistency
groups per system
255

Total FlashCopy volume capacity per I/O group
4096 TB

IP Partnership Properties
Inter-cluster IP partnerships per system
1
A system may be partnered with up to three remote systems. A maximum of one of those can be IP and the other two FC.
I/O groups per system
2
The nodes from a maximum of two I/O groups per system can be used for IP partnership.
Inter site links per IP partnership
2
A maximum of two inter site links can be used between two IP partnership sites.
Ports per node
1
A maximum of one port per node can be used for IP partnership.
Internal Storage Properties
SAS chains per control enclosure
2

Expansion enclosures per Storwize V7000 SAS chain
5
see notes
Up to 5 expansion enclosures on SAS port 1 and up to 4 expansion enclosures on SAS port 2
Expansion enclosures per Storwize V7000 control enclosure
9

Drives per Storwize V7000 I/O group
240

Drives per Storwize V7000 system
960
Maximum requires a system containing four control enclosures, each with the maximum number of expansion enclosures
Expansion enclosures per Storwize V7000 Gen 2 SAS chain
10

Expansion enclosures per Storwize V7000 Gen 2 control enclosure
20

Drives per Storwize V7000 Gen 2 I/O group
504

Drives per Storwize V7000 Gen 2 system
1056

Min-Max drives per enclosure
0-12
or
0-24
Limit depends on the enclosure model
Simultaneous autosparingDrives per system
RAID Properties
RAID arrays per system
128

Encrypted RAID arrays per system
128

Min-Max member drives per RAID-0 array
1-8

Min-Max member drives per RAID-1 array
2-2

Min-Max member drives per RAID-5 array
3-16

Min-Max member drives per RAID-6 array
5-16

Min-Max member drives per RAID-10 array
2-16

Hot spare drives
-
No limit is imposed
External Storage System Properties
Storage system WWNNs per system (cluster)
1024

Storage system WWPNs per system (cluster)
1024

WWNNs per storage system
16

WWPNs per WWNN
16

LUNs (managed disks) per storage system
-
No limit is imposed beyond the managed disks per system limit
System and User Management Properties
User accounts per system
400
Includes the default user accounts
User groups per system
256
Includes the default user groups
Authentication servers per system
1

NTP servers per system
1

iSNS servers per system
1

Concurrent open SSH sessions per system
32

Event Notification Properties
SNMP servers per system
6

Syslog servers per system
6

Email (SMTP) servers per system
6
Email servers are used in turn until the email is successfully sent
Email users (recipients) per system
12

LDAP servers per system
6


change
Extents

The following table compares the maximum volume, mdisk and system capacity for each extent size.

Extent size (MB)
Maximum non thin-provisioned volume capacity in GB
Maximum thin-provisioned volume capacity in GB
Maximum Compressed Volume Size**
Maximum MDisk capacity in GB
Total storage capacity manageable per system*
16
2048 (2 TB)
2000

2048 (2 TB)
64 TB
32
4096 (4 TB)
4000

4096 (4 TB)
128 TB
64
8192 (8 TB)
8000

8192 (8 TB)
256 TB
128
16,384 (16 TB)
16,000

16,384 (16 TB)
512 TB
256
32,768 (32 TB)
32,000

32,768 (32 TB)
1 PB
512
65,536 (64 TB)
65,000

65,536 (64 TB)
2 PB
1024
131,072 (128 TB)
130,000
96TB**
131,072 (128 TB)
4 PB
2048
262,144 (256 TB)
260,000
96TB**
262,144 (256 TB)
8 PB
4096
262,144 (256 TB)
262,144
96TB**
524,288 (512 TB)
16 PB
8192
262,144 (256 TB)
262,144
96TB**
1,048,576 (1024 TB)
32 PB