  • Closed as program error.

Error description

  • The customer's application has responses with the following
    Content-Type in the response header:
    
       Content-Type: application/json; charset=utf-8
    
    The actual content in these responses is text but is not
    formatted like JSON, such as:
    
       //OK[1,["06-22-2021"],0,7]
    
    When they generate a test with the default options with RPT
    10.5, the test shows the response Content as "null".
    
    If they turn off the JSON data transform, then the response
    Content shows the actual text.
    

Local fix

  • To work around this, disable the "Convert to JSON format" option
    in the Available transformers in Window->Preferences->Test->Test
    Generation and regenerate the test from the recording.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * RPT Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH51533

  • Reported component name

    PERF TESTER WIN

  • Reported component ID

    5724J9601

  • Reported release

    A50

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-12-16

  • Closed date

    2023-03-30

  • Last modified date

    2023-03-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PERF TESTER WIN

  • Fixed component ID

    5724J9601

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A50","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
30 March 2023