Problem
This document discusses a likely cause of a CWBCO1003 RC10013 message when connecting with Access for Windows and or Access Client Solutions.
Resolving The Problem
The CWBCO1003 RC10013 is reporting a Microsoft Winsock error code 10013 - Access Denied.
This is normally going to be caused by firewall security type software running within Windows that is blocking an IBM i Access executable module access to connect to the network.
The IBM i Access communication executables are going to start with the prefixes of CWB* or PCS*; therefore, you should add rules to the firewall security type software on the Windows PC to allow those modules access to the network.
This is normally going to be caused by firewall security type software running within Windows that is blocking an IBM i Access executable module access to connect to the network.
The IBM i Access communication executables are going to start with the prefixes of CWB* or PCS*; therefore, you should add rules to the firewall security type software on the Windows PC to allow those modules access to the network.
[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"6.1.0"},{"Type":"MASTER","Line of Business":{"code":"LOB66","label":"Technology Lifecycle Services"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSRQKY","label":"IBM i Access Client Solutions"},"ARM Category":[{"code":"a8m0z0000000CTpAAM","label":"IBM i Access-\u003EAccess Client Solutions"}],"ARM Case Number":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"All Versions"}]
Historical Number
622371252
Was this topic helpful?
Document Information
Modified date:
18 November 2024
UID
nas8N1011187