Error description

  • Code to set ptrash as local was designed to be
    enabled if afmRevalOpWaitTimeout remains at
    its default value. But it's highly unlikely it
    stays default in a customer environment.
    

Local fix

  • Setting the afmRevalOpWaitTimeout to its default value
    of 180 will ensure ptrash is set to local
    

Problem summary

  • Code to set ptrash as local was designed to be
    enabled if afmRevalOpWaitTimeout remains at
    its default value. But it's highly unlikely it
    stays default in a customer environment.
    

Problem conclusion

  • This problem is fixed in 5.1.6.1
    To see all Spectrum Scale APARs and their respective
    Fix solutions refer to page:
    https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_
    apars.html
    
    Benefits of the solution:
    Ability to tune ptrash local bit setting behavior by
    tuning the afmRevalOpWaitTimeout/
    
    Work around:
    Setting the afmRevalOpWaitTimeout to its default value
    of 180 will ensure ptrash is set to local.
    
    Problem trigger:
    afmRevalOpWaitTimeout being set to a non-default value
    causing ptrash local bit setting code to not take
    effect.
    
    Symptom:
    Unexpected Behavior
    
    Platforms affected:
    All Linux OS environments (serving as AFM Gateway nodes)
    
    Functional Area affected:
    AFM
    
    Customer Impact:
    High Importance
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ44491

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-12-06

  • Closed date

    2022-12-06

  • Last modified date

    2022-12-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
06 December 2022