Error description
We found the NVMe and SSD disks were put into one DA when RG creation. The disk size is almost the same, and both have spin = 0, then GNR thinks it's the same type of disk.
Local fix
Problem summary
Problem description in customer terms: We found the NVMe and SSD disks were put into one DA when RG creation. The disk size is almost the same, and both have spin = 0, then GNR thinks it's the same type of disk.
Problem conclusion
This problem is fixed in 5.1.6.1 To see all Spectrum Scale APARs and their respective Fix solutions refer to page: https://public.dhe.ibm.com/storage/spectrumscale/spectrum_scale_ apars.html Benefits of the solution: NVMe and SSD disks are placed into different declustered arrays even when they have same size. Work Around: None Problem trigger: NVMe and SSD disks have same size. Symptom: Unexpected Results/Behavior Platforms affected: Linux Only Functional Area affected: ESS/GNR Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ44440
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-12-06
Closed date
2022-12-06
Last modified date
2022-12-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Line of Business":{"code":"LOB26","label":"Storage"}}]